The overall aim of the study is to assess the reliability and validity of Autocad software to measure JPS in PFPS, especially: 1. To assess the intra-tester and between day reliability of measurement of JPS using Autocad software. 2. To assess the validity of these measurements against those found during an IKD.
Patellofemoral pain syndrome (PFPS) is a common painful musculoskeletal condition that affects physically active young adults and adolescents. Joint position sense (JPS) is considered as a component of proprioception as it provides the clinician with information regarding the accuracy of movement as well as its relationship with movement performance and injuries. Therefore researchers use advanced instruments as 3 D video systems and isokinetic dynamometer. Since these instruments are less portable and expensive, therefore researchers used another method to evaluate JPS using high precision software using video analysis and markers in the joints. Unfortunately, video analysis requires difficult and time-consuming tasks and that this slow the evaluation process. Although immediate feedback could help physiotherapists and athletic trainers to monitor athletes and make decisions during the training session and the rehabilitation process, such immediacy is not available for proprioceptive tests in field situations. Autocad software is available and inexpensive and provides immediate feedback
Study Type
OBSERVATIONAL
Enrollment
38
The participants will be prepared for image-capture data collection by putting four squared markers on leg and thigh.Each subject will extend his/her leg and make two angles from the resting position (90º) to the full extension, photos will be taken. The tested leg passively moved by the researcher through 20° to 60° of knee extension, the participant will be instructed to actively move that leg to the target angle and hold it in this position another photograph will be taken. The angles will be measured using the AutoCAD software. Knee JPS measurements will also be collected using an IKD by same steps
Faculty of Physical therapy, Cairo University
Giza, Egypt
Concurrent validity of Autocad software
correlation between absolute angular error of Autocad software and isokinetic system
Time frame: one day
Intrarater reliability of
same investigator will repeat joint positsion sense by Autocad software
Time frame: 48 hours