This study evaluates if trainees can accurately rule out dilation of the renal collecting system on ultrasound (hydronephrosis) using hand-carried ultrasound (HCU). Trainees will undergo a short ultrasound training program. Patients will be adults that are hospitalized and have acute or subacute kidney dysfunction. The investigators will assess sensitivity, specificity, positive and negative predictive value of HCU compared to radiology performed ultrasound, and calculate potential cost savings to the patient and to the healthcare system.
Hand-carried ultrasound is an increasingly popular imaging modality and is widely used by emergency physicians, intensivists, trauma doctors and cardiologists. Renal ultrasonography is commonly ordered for patients with acute kidney injury, with a main focus on identifying obstruction of the collecting system, a rare but potentially reversible cause of acute kidney injury. This study's aim is to evaluate if nephrology and internal medicine trainees can accurately rule out dilation of the renal collecting system on ultrasound (hydronephrosis) using hand-carried ultrasound (HCU). Trainees will undergo a short, uniform and well described ultrasound training program. Patients will be adults that are hospitalized and have acute or subacute kidney dysfunction. The investigators will assess sensitivity, specificity, positive and negative predictive value of HCU compared to radiology performed ultrasound, and calculate potential cost savings to the patient and to the healthcare system.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
6
Hand-carried ultrasound of both kidneys to detect the presence or absence of hydronephrosis. Device used will be the lumify portable ultrasound equipped with the C5-2 curved array transducer (Philips, USA).
Barnes Jewish Hospital
St Louis, Missouri, United States
Number of Participants With Absence of Hydronephrosis
The number of participants for whom none of the kidneys imaged with hand-carried ultrasound have hydronephrosis (dilation of the collecting system) is reported
Time frame: Through study completion, up to an average of 1 day
Direct Costs of Hand-carried Ultrasound
Direct costs in $ of hand-carried ultrasound will be calculated and compared to the costs of radiology performed ultrasound. For hand-carried ultrasound, this will include costs of purchasing the device, training costs, yearly depreciation of the hand-carried ultrasound device. For radiology performed ultrasound, this will include the sonographer's fee, radiologist fee for interpretation of the result, transportation fee by hospital transport and depreciation of the ultrasound machine.
Time frame: Through study completion, up to an average of 1 day