Obstructive sleep apnea (OSA) is a common and frequently-occurring disease. The incidence of OSA is more than 4% in general population, and as high as 20% - 40% in the elderly. At present, CPAP machines commonly used for OSA treatment includes traditional pressure fixed single-level CPAP machine and automatic pressure regulation CPAP machine. Studies have shown that the CPAP treatment pressure of OSA patients is normally below 11 cmH2O. Since the condition of OSA patients and the required CPAP treatment pressure may change over time, a CPAP machine with automatic pressure regulation function may theoretically better meet the needs of treatment. However, a recent large-scale clinical study with an average follow-up of four years showed that there was little need to change CPAP treatment pressure after titration. Although different types of CPAP have different functions, the basic principle is to keep the upper airway open and unobstructed to eliminate sleep apnea and hypopnea by continuously applying positive pressure to the upper respiratory tract through an air pump. A complex CPAP machine with functions such as pressure regulation, boost delay, end-expiratory pressure release will cost more than a single-function CPAP machine. Some patients from poor areas, even with severe OSA, may give up treatment when they can not afford CPAP machines that have not yet been included in national health insurance in China. In view of the current economic level in China, it is urgent to find an inexpensive and effective CPAP machine for the treatment of OSA and related complications. Recently, Guangzhou Yinghui Medical Technology Co., Ltd.and State Key Laboratory of Respiratory Disease have developed a new simple CPAP machine. The CPAP treatment pressure is fixed at the factory to 6 cm H2O (SKL), 8 cm H2O (SKM) and 10 cm H2O (SKH). Compared to traditional CPAP machine, only a power switch button is attached on the body, and the additional adjustment devices including display screen are removed, which not only reduces the cost of the CPAP machine, but also facilitates the operation of patients.
Study Design: A randomized, cross-over and double blind study . Objective: To investigate the efficacy of simple device of continuous positive airway pressure (CPAP) in the treatment of obstructive sleep apnea (OSA). Methods: A randomized, cross-over and double blind study would be performed on 100 OSA patients using both simple CPAP and traditional CPAP during overnight polysomnography. Pressure for CPAP treatment would be manual titrated. The sleep apnea hypopnea index (AHI), arousal index (ArI), Oxygen desaturation Index (ODI), sleep structure and the preference of CPAP model were to be observed.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
100
Patients used simple CPAP and conventional fixed CPAP during overnight polysomnography.
Patients used simple CPAP and Auto CPAP during overnight polysomnography.
The First Affiliated Hospital of Guangzhou Medical University
Guangzhou, Guangdong, China
Apnea Hypopnea Index
Total number of apneas and hypopneas×60/total sleep time
Time frame: One full night
Arousal Index
Total number of arousals×60/total sleep time
Time frame: One full night
Oxygen Desaturation Index
Total number of oxygen desaturations≥3%×60/total sleep time
Time frame: One full night
Sleep structure
Sleep stage distribution(N1, N2, N3, NREM)
Time frame: One full night
Adverse effects
Using questionnaire to assess adverse effects including dyspnea, noise, bloating, et al
Time frame: Onefull night
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.