The objective of this study is to assess the accuracy of the Apple Watch 4 Series watch in generating an ECG that is suitable for determination of heart rhythm compared to rhythms monitored via telemetry. Secondary objective is to assess the accuracy of the Apple Watch 4 series watch in identifying atrial fibrillation when it is present.
The study will assess the accuracy of the Apple watch 4 series watch when worn by post-operative cardiac surgery patients after they have transferred from the ICU to the cardiac telemetry unit. During testing each subject will wear: 1. An Apple Watch 4 series watch for no more than 5 minutes. 2. Standard continuous telemetry monitor The location of the watch (left or right wrist) will be randomly assigned. Heart rate and rhythm will be assessed by obtaining tracings from the Apple Watch 4 series watch while at the same point in time obtaining tracings from a standard telemetry monitor. ECGs from the Apple Watch 4 will be collected by asking the patient to place his/ her finger on the digital crown of the Apple Watch 4 for 30 seconds. The rhythm displayed by the Apple Watch 4 will be viewed on the Apple health app (available on the iPhone 8) and will be saved for subsequent viewing and analysis. Each enrolled patient will have a minimum of three assessments of heart rhythm per day for at least two days, generating a minimum of six data points per patient. After conclusion of the study for each subject, the ECG's from the health app pertaining to that subject will be reviewed by a board certified cardiologist as will the telemetry tracings. In order to obtain tracings of new onset post-operative atrial fibrillation. 50% of the subjects enrolled will be in sinus rhythm and 50% will be in atrial fibrillation at the time of enrollment.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
OTHER
Masking
NONE
Enrollment
50
tracings from the apple watch 4 series watch
tracings from the continuous telemetry monitor
Cleveland Clinic
Cleveland, Ohio, United States
Heart rate accuracy compared to telemetry
Apple Watch 4 Series heart rate monitor device accuracy compared to standard continuous telemetry monitor. This will be expressed by the correlation coefficient.
Time frame: 5 minutes
Heart rhythm accuracy compared to telemetry
Apple Watch 4 Series heart rhythm device accuracy compared to standard continuous telemetry monitor. This will be expressed by the correlation coefficient.
Time frame: 5 minutes