Oxygen therapy is a cornerstone in treating patients with severe chronic obstructive pulmonary disease. Usually, oxygen supplementation is delivered using constant-flow rates. Varying oxygenation levels may occur throughout patients´ changing activity. There is some evidence available that an auto-regulating oxygen flow system (FreeO2), which adjusts the oxygen flow automatically to prevent desoxygenation could be beneficial in comparison to a constant oxygen dose of 2 liter/min during walking. However, these possible benefits are unknown if the FreeO2 is compared to a constant oxygen dose according to the individual prescription. Therefore, the primary aim of this study is to investigate the effects of auto-regulated oxygen flow rates compared to constant oxygen flow rates as prescribed according to international guidelines on walking capacity in patients with COPD.
Rationale: Hypoxemia is frequently observed in COPD and thus can negatively impact exercise tolerance. Supplemental oxygen or long-term oxygen therapy is recommended to ensure that the patient is still able to manage his daily life. Usually, oxygen supplementation is delivered using constant flow rates during day- and nighttime or as needed. However, studies have shown, that auto-regulated oxygen flow systems (FreeO2) may enhance the patients endurance, lower the time in severe hypoxemia and increase the time spent within the SpO2 target range. Aim of this study is to investigate the effects off an auto-regulated oxygen flow system in hypoxemic COPD patients on the patient´s endurance, the oxygen saturation, the pCO2 blood level as well as on heart rate and breathing frequency compared to the effects off the prescribed constant flow (according to the British Thoracic Society Guidelines for Home Oxygen Use in Adults) during an endurance shuttle walk test (ESWT). Additionally, patients experience, e.g. comfort and Preference of the Oxygen-delivery System will be documented. Design: This study is a randomized, controlled cross-over trial. Following an initial incremental shuttle walk test (ISWT) in order to determine the participants individual maximal walking capacity, the participant will perform 2 endurance shuttle walk tests (ESWT) at 85% of the maximal walking rate. In randomized order, the participants will perform one ESWT with constant flow as prescribed and one ESWT with the auto-regulated oxygen flow system.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
55
Oxygen supply during ESWT, once with the prescribed constant oxygen flow and once using an auto-regulated oxygen flow system setting the SpO2 target at 92%.
Schoen Klinik Berchtesgadener Land
Schönau am Königssee, Bavaria, Germany
Endurance time
Change of Walking Duration during the ESWT
Time frame: Day 1 and Day 2
Change of oxygen saturation during the endurance shuttle walk test.
SpO2 measured by continuous transcutaneous recordung via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland).
Time frame: Day 1 and Day 2
Time to desaturation (SpO2 <=90%) and to severe desaturation (SpO2 <=85%)
SpO2 measured by continuous transcutaneous recordung via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland) and FreeO2 Device.
Time frame: Day 1 and Day 2
Change of capillary partial pressure of CO2 (pCO2) during endurance shuttle walk test
pCO2 measured by capillary blood gases taken before and after the ESWT.
Time frame: Day 1 and Day 2
Change of capillary partial pressure of O2 (pO2) during endurance shuttle walk test
pO2 measured by capillary blood gases taken before and after the ESWT.
Time frame: Day 1 and Day 2
Change of partial pressure of CO2 (pCO2) during endurance shuttle walk test
pCO2 measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Time frame: Day 1 and Day 2
Change of heart rate during endurance shuttle walk test
Heart rate measured by continuous transcutaneous recordung via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland).
Time frame: Day 1 and Day 2
Change of breathing frequency during endurance shuttle walk test
Breathing frequency during the ESWT measured by ApneaLink Air™ (ResMed, ...)
Time frame: Day 1 and Day 2
Patients Preference due to oxygen delivery system
Patients will be asked to rate their experienced comfort after each ESWT
Time frame: Day 1 and Day 2
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.