Multi-center, prospective, open-label, single-arm, first-in-human clinical investigation. The patient enrollment will be as follow: initial 5 patients enrolled at PI site. The other remaining patients will be enrolled in the three sites only after positive evaluation of the 3 months Follow Up (FU) interim report analysis by Data Safety Monitoring Board (DSMB). The Patients enrolled in this clinical investigation will undergo a scheduled surgery aiming to reconstruct iliac crest bone defect using GreenBone Implant. After surgery, the Patients will be monitored at pre-scheduled visits up to 6 months. The FU will be extended at 12 months only in case of no complete healing and/or in case of no resolved SAE at the 6 months FU visit. Adverse events, pain, quality of life and X-ray will be evaluated at scheduled follow-up visits. An independent DSMB will review the safety reports at regular intervals and Serious Adverse Events (SAE) as soon as reported, to protect Patients participating in the study. As specified before, an adaptive interim analysis will be performed when at least 5 Patients will have completed the 3 month follow up visit, (V5). The DSMB will review the results of the interim analysis with respect to the primary endpoint (safety) in order to continue the study up to 15 Patients.
This is a pre-market multi-centre, national, open label, single-arm, study to evaluate the safety and performance of a Class III medical device (GreenBone Implant) for iliac crest reconstruction following bone graft harvesting for pelvic fusion. During pelvic fusion a considerable part of the iliac crest is removed and it is used as autologous bone graft for the fusion of the pubis symphysis. The bone defect that is formed in the iliac crest is usually filled with bone obtained from the cows (bovine xenograft) and or human donors (allograft). This carries the risk of transferring disease from animals and/or humans to the patient; there is also a risk of host local allergic reaction. Bone substitutes are devoid of the above risks and therefore they could be used alternatively to xenografts and allografts. GreenBone is a ceramic resorbable bone scaffold that has very similar structure to bone. It can be produced in large quantities, shaped easily and sterilised without losing its properties. Consequently, it is an ideal substitute that could be used to fill bone defects. This study will assess the safety of using GreenBone to reconstruct iliac crest defects. Moreover it will assess its capacity of promoting new bone formation. The investigators will recruit 15 patients who will undergo pelvic fusion and instead of bovine xenograft the investigators will use the GreenBone implant for the iliac crest reconstruction. Patients will be followed up for 6 months in total. Safety will be evaluated by monitoring local and potential systemic reactions; its bone forming capacity will also be assessed by its integration into the iliac crest.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
15
When autologous bone graft is needed for the treatment of non-unions or bone defects, is harvested from the pelvic iliac crest. Harvested tricortical graft blocks are used to facilitate fusion of joints (ie pubis symphysis, sacroiliac joint), to structurally support metaphyseal areas of articular impaction injuries and to fill in metaphyseal bone voids. The GreenBone device, with its inherent physical and biomimic properties, possesses similar structural properties to bone, thus, being the ideal material to be used for the treatment of the bone defect (3- 4cm) induced from the harvested tricortical iliac crest, restoring therefore the pelvic anatomy and minimising the risk of chronic pain, haematoma formation and herniation of the abdominal contents.
Department of Trauma and Orthopaedic Surgery, Leeds General Infirmary
Leeds, United Kingdom
Safety Evaluation assessed by Evaluation of adverse events rate
Evaluation of adverse events rate during the study period. All adverse occurrences (serious/non-serious or device related/non-device related) will be recorded prospectively, categorized and evaluated for causality using defined criteria.
Time frame: Overall study period up to 6 months
Device Implant Technical Success
Technical Success, defined as successful delivery of the bone substitute in the target defect bone evaluated at V2 (at surgical procedure);
Time frame: At the end of surgical procedure (visit 2, 1 day)
Bone regeneration evaluation
Evaluation of the bone regeneration in the area of intervention, by means of X-ray and/or CT examination by a radiologist, on visit V3, V4, V5, V6, V7; X-ray scoring systems have been implemented according to the criteria proposed by Lane and Sandhu (bone formation, union and remodeling) (Lane 1987)
Time frame: At the end of visits 3, 4, 5, 6, 7 (respectively performed 1, 2, 3, 6, 12 months after the surgery, each visit is 1 day)
Quality of Life evaluation
Evaluation of Quality of Life by means of a validated EuroQol questionnaire administered at every visit from V1 to V6/V7 (excluding visit 2) (Price 1983)
Time frame: At screening visit (V1) and at the end of visits 3, 4, 5, 6, 7 (respectively performed 1, 2, 3, 6, 12 months after the surgery, each visit is 1 day)
Evaluation of Pain
Evaluation of degree of pain perceived by the Patient, by means of a Visual Analogue Score (VAS) that a scale with 10 points, from 0 to 10. 0 indicates "no pain at all" and 10 the "worst pain ever"
Time frame: between 1 and 6 months
Treatment tolerability
Evaluation of global tolerability to treatment of Patient (by the Investigator), through a standardized EuroQol questionnaire, on every visit from V3 to V6/V7
Time frame: At the end of visits 3, 4, 5, 6, 7 (respectively performed 1, 2, 3, 6, 12 months after the surgery, each visit is 1 day)
Reinterventions number
Evaluation of the number of re-interventions occurring for the Patient throughout the . 6 months observation period.
Time frame: between 1 and 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.