This study sets out to evaluate the EpiMaster application software for use in predicting the refractive change induced by a trans-epithelial phototherapeutic keratectomy (TE-PTK) procedure in eyes with irregularly irregular astigmatism. If validation criteria are met during the observational phase, the software refractive prediction will be used to plan the refractive correction in TE-PTK treatments.
Complications after laser eye surgery can often result in the front surface of the eye (the cornea) becoming irregular, which causes visual symptoms such as halos, glare, starbursts, double vision, and reduced contrast sensitivity. For the past 20 years, corneal irregularities have been treated using wavefront-guided ablation, topography-guided ablation or trans-epithelial phototherapeutic keratectomy (TE-PTK). Topography-guided ablation is the most effective treatment for certain types of irregularity and works by using a laser to remove tissue from the cornea in a pattern derived from a topography scan (a measurement of the shape and curvature of the front of the eye) designed to make the corneal surface more regular. However, topography-guided ablation is less effective for other types of irregularity. In these cases, the corneal epithelium (the layer of skin on the surface of the cornea) has changed in thickness to partially hide the irregularity on the body of the cornea under the epithelium (the stroma). The epithelium does this by becoming thinner over peaks and thickening over troughs in the stroma. Therefore, the topography measurement can only detect the proportion of the irregularity that has not been hidden by the epithelium, hence reducing its effectiveness. The preferred treatment option is TE-PTK; the laser treatment is applied onto and through the epithelium, breaking through to the stroma where the epithelium is thinnest, thus removing tissue from the peaks on the stroma resulting in a more regular surface. The main weakness of TE-PTK is that it may unpredictably change the refraction to become more short-sighted or more long-sighted or change the astigmatism. To improve this, we have developed the Epimaster software that simulates a TE-PTK treatment and predicts the change in refraction. The aim of the study is to validate the refractive prediction produced by the Epimaster software by comparing this to the achieved result in the patients treated. The treatment received by the patient will be the same as has been used routinely for the past 20 years.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
45
The MEL 90 excimer laser will be used to ablate the corneal epithelium and stroma to a pre-defined depth, using the epithelium as a natural masking agent to smooth the stromal surface.
The MEL 90 excimer laser will be used to ablate the corneal epithelium and stroma to a pre-defined depth, using the epithelium as a natural masking agent to smooth the stromal surface.
The EpiMaster Application Software imports epithelial thickness data and corneal front surface topography data, and uses this to calculate the refractive change that would be induced by a trans-epithelial PTK treatment.
London Vision Clinic
London, United Kingdom
The tendency of manifest sphere, cylinder and axis
The correct tendency of manifest sphere, cylinder and axis should be achieved in 90% of cases, where tendency refers to: 1. The sign of the predicted and the post-operative sphere is equal for predicted sphere values greater than absolute value 0.50 D (confidence limit) 2. The sign of the predicted and the post-operative cylinder is equal (same cylinder format setting like e.g. plus cylinder format) for predicted cylinder values greater than absolute value 0.50 D (confidence limit) 3. The cylinder axis of the predicted and the post-operative cylinder do not deviate by more than ±45° for predicted cylinder values greater than absolute value 0.50 D (confidence limit) 4. In none of the cases the prediction in sphere and cylinder is more than absolute value 2.00 D off the post-operative values.
Time frame: 3-12 months
Standard deviation of SEpostop-SEpredicted
Standard deviation of SEpostop-SEpredicted at each follow-up time point (represents the scatter of the refractive outcome), where SEpredicted is the refractive outcome predicted by the EpiMaster application software.
Time frame: 12 months