Invistigators study both supraglottic airway devices; the classic LMA and the I GEL mask are satisfactory devices providing high airway leaking pressures. Although both devices provide high airway leaking pressures, Invistigators study revealed that the I gel mask provides a better seal with the glottic aperture and shorter time of insertion than cLMA. Both devices showed also effective ventilation, more hemodynamic stability and no episode of hypoxia with minimal post-operative complications.
Because of the advantages of supraglottic devices over the conventional endotracheal intubation, they are now widely used in ventilation. The classic LMA is a first generation simple airway tube consists of two parts, the tube and the cuffed peri-laryngeal sealer mask which is designed to provide an oval seal around the laryngeal inlet. It is made of medical grade silicone; it can be autoclaved and reused many times. I gel is a new type of laryngeal mask and doesn't have an inflatable cuff. Because of its thermoplastic elastomer structure, it exactly adapts to the supraglottic tissue by binding with body temperature, thus minimising air leakage. The aim of this study is to compare between cLMA and I gel regarding insertion success rate, the time of insertion, leaking pressure, assessment of position by fiber optic, hemodynamic, Spo2 for each device during insertion and maintenance of general anaesthesia and postoperative complications in obese patients. This study was conducted in Kasr Al-Ainy Teaching Hospital, after obtaining approval from Kasr Al-Ainy hospital research ethical committee, written informed consents were taken from 50 patients, all of whom completed this study. Patients were randomly allocated into 2 equal groups, 25 each, according to the inclusion and exclusion criteria. * GA (n=25) in which classic laryngeal mask was used for ventilation. * GB (n=25) in which I gel was used for ventilation. In our study the median insertion time was in I gel lesser than cLMA (9 s vs 10 s) respectively that was statistically significant but clinically insignificance. Higher leaking pressure was in I gel group (25cmh2o vs 18cmh2o) than cLMA group that was statistically significant. Our main finding in the study was that both supraglottic airway devices; the classic LMA and the I GEL mask are satisfactory devices providing high airway leaking pressures. Although both devices provide high airway leaking pressures, our study revealed that the I gel mask provides a better seal with the glottic aperture and shorter time of insertion than cLMA. Both devices showed also effective ventilation, more hemodynamic stability and no episode of hypoxia with minimal postoperative complications.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
50
The aim of this study is to compare between cLMA and I gel regarding insertion success rate, the time of insertion, leaking pressure, assessment of position by fiber optic, hemodynamic, Spo2 for each device during insertion and maintenance of general anaesthesia and postoperative complications in obese patients
I gel is a new type of laryngeal mask and doesn't have an inflatable cuff. Because of its thermoplastic elastomer structure, it exactly adapts to the supraglottic tissue by binding with body temperature, thus minimising air leakage
Ahmed Abdalla Mohamed
Cairo, Egypt
Time of insertion of each device .
Invistigators study Time of insertion of each device,Laryngeal Mask Airway and I gel
Time frame: Half an hour
Leaking pressure of each device.
Invistigators study Leaking pressure of each device,Laryngeal Mask Airway and I gel
Time frame: Half an hour
Confirmation of position by fiber optic
Invistigators study Confirmation of position by fiber optic of each device,Laryngeal Mask Airway and I gel
Time frame: Half an hour
Blood Pressure
Investigators recorded a baseline reading of systolic blood pressure and diastolic blood pressure before insertion of both devices. A second reading was taken after insertion of both devices, just before removal. The fourth reading was recorded 1 min after removal of both devices.
Time frame: 24 hours
Heart Rate
Investigators recorded a baseline reading of heart rate, before insertion of both devices. A second reading was taken after insertion of both devices, just before removal. The fourth reading was recorded 1 min after removal of both devices.
Time frame: 24 hours
Oxygen saturation
Investigators recorded a baseline reading of Oxygen saturation before insertion of both devices. A second reading was taken after insertion of both devices, just before removal. The fourth reading was recorded 1 min after removal of both devices.
Time frame: 24 hours
Postoperative complications
With regard to postoperative complications, after removal of the device, post operative blood stain in laryngeal mask and I gel
Time frame: 24 hours