This investigation is a prospective, multicenter clinical investigation. It is anticipated that a total of eighty (80) subjects will be enrolled at approximately 4-7 sites. The clinical investigation has been designed to follow the surgeon's standard of care for joint arthroplasty subjects, which entails clinical evaluation on a regular ongoing basis, or as needed should the subject become symptomatic in the treated joint.
The objective of this clinical investigation is to demonstrate the safety and efficacy/performance of the ReUnion RSA System. Efficacy/performance of the procedure will be measured the American Shoulder and Elbow Surgeons (ASES) Shoulder Score. Safety of the ReUnion RSA System will be demonstrated through reporting of device-related intra-operative and post-operative Adverse Events (AEs). Enrolled subjects will be assessed at Pre-Operative, Operative/Discharge, and at 6 Weeks, 6 Months, 12 Months, 24 Months and annually thereafter up to 10 years following the index procedure.
Study Type
OBSERVATIONAL
Enrollment
102
The ReUnion RSA System is designed as a reverse total shoulder endoprosthesis to address unrepairable gross rotator cuff tear, rotator cuff arthropathy with pseudoparalysis of the shoulder joint, advanced arthritic and rheumatic disorders affecting the shoulder joint, and failed previous shoulder arthroplasty. The ReUnion RSA System is comprised of a Humeral Cup, Humeral Insert, Glenosphere, Glenoid Baseplate and Screws. The intended purposes of the ReUnion RSA System are to achieve pain relief, improvement of range of motion and restoration or improvement of the shoulder function while ensuring long-term replacement of the shoulder joint with sufficient stability of all endoprosthesis components.
Great Plains Orthopedics
Peoria, Illinois, United States
Steadman Hawkins Clinic of the Carolinas
Greenville, South Carolina, United States
Tennessee Orthopaedic Alliance
Nashville, Tennessee, United States
American Shoulder and Elbow Surgeons (ASES) Shoulder Score
This is a mixed outcome reporting measure, applicable for use in patients with shoulder pathology regardless of diagnosis and consists of a pain visual analog scale (VAS) and 10 functional questions. The primary endpoint of the clinical investigation is to demonstrate non-inferiority of the device to the selected literature controls, as measured by the ASES Shoulder Score at 24 Months post-operative. Scores range from 0 to 100 with a score of 0 indicating a worse shoulder condition and 100 indicating a better shoulder condition.
Time frame: 24 Months
Safety Will be Measured by Capturing the Incidence Rate of Device-related Intra-operative Adverse Events.
Secondary outcome measures to assess safety by capturing the incidence rate of device-related intra-operative adverse events.
Time frame: 24 months
Safety Will be Measured by Capturing the Incidence Rate of Device-related Post-operative Adverse Events.
Secondary outcome measures to assess safety by capturing the incidence rate of device-related post-operative adverse events.
Time frame: 24 months
Efficacy Will be Measured by Monitoring All Implant Survivorship in All Subjects Who Have the Reverse Total Shoulder Endoprosthesis With the ReUnion RSA System.
Secondary outcome measures to assess efficacy by monitoring all implant survivorship in all subjects who have the reverse total shoulder endoprosthesis with the ReUnion RSA System.
Time frame: 24 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.