Crossover study comparing Moviprep (for bowel cleansing) with a new gel-based colon cleansing agent before colonoscopy
Crossover study comparing Moviprep (for bowel cleansing) with a new gel-based colon cleansing agent before colonoscopy. Study performed in health subjects.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
DOUBLE
Enrollment
16
Colonic cleansing before colonoscopy and CT colonografi
Zuh
Køge, Region of Zealand, Denmark
Boston Bowel preparation scale (BBPscale)
Visual assessment of the degree of bowel cleansing performed by the endoscopist (blinded). Right colon, colon transversum, and left colon are each judged on a scale from 0-3 with higher scores indicating better cleansing. Range of score between 0-9.
Time frame: Performed during the endoscopy procedure
Adverse events related to intervention
Any adverse event related to the intervention observed by investigators or as reported by the participant
Time frame: Assessed 4 hours after last intake of cleansing product
Blood pressure
mmHg systolic and diastolic measured on right or left arm.
Time frame: Measured immediately before the colonoscopy starts, and every 5 minutes during colonoscopy and immediately after the end of the examination
Saturation
Oxymeter measuring the saturation of hemoglobin with oxygen as a percentage of 0-100%.
Time frame: Measured immediately before the colonoscopy starts, and every 5 minutes during colonoscopy and immediately after the end of the examination
Heart rate
Heart rate
Time frame: Measured immediately before the colonoscopy starts, and every 5 minutes during colonoscopy and immediately after the end of the examination
Respiration frequency
Respiration frequency
Time frame: Measured immediately before the colonoscopy starts, and every 5 minutes during colonoscopy and immediately after the end of the examination
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.