This clinical trial investigates the safety and the preliminary clinical benefit of the hemiverse shoulder prosthesis. Implantation of this newly developed hemi-prosthesis is intended for patients who do not qualify for a regular reverse or hemi-prosthesis due to severe medical conditions, poor bone stock or critical status of the rotator cuff. The expected benefit is, that patients will have a minimally invasive surgical procedure, only addressing the humeral shaft, however with the biomechanical advantage of a total reverse shoulder prosthesis, meaning, that with a minimally invasive surgery a comparable result as with a regular total shoulder prosthesis is accomplished. Patients will be closely monitored within the study protocol for 18 months and thereafter in regular interval was as with a normal prosthetic followup.
This clinical trial investigates the safety and the preliminary clinical benefit of the hemiverse shoulder prosthesis. Implantation of this newly developed hemi-prosthesis is intended for patients who do not qualify for a regular reverse or hemi-prosthesis due to severe medical conditions, poor bone stock or critical status of the rotator cuff. To evaluate the clinical condition of the patient a clinical examination with thorough control of the blood parameters (hemoglobin, leucocytes, platelets, infection parameters) and including constant score and the quick dash score will be performed before the operation. To evaluate the bone stock and the musculature a conventional radiological status and a computed tomography of the shoulder will be performed. Surgical procedure: A delto-pectoral approach is preferred. The incision starts immediately lateral to the coracoid tip and extends to the insertion of the deltoid on the Humerus. The subscapularis tendon is exposed and detached from the humerus. The humeral head is exposed and dislocated from the joint using an oscillating saw the humeral head is resected. The shaft is prepared to receive a regular humeral stem which is definitely implanted with 0° retroversion. A trial implant is inserted and reduced into the joint. Free mobility of the joint is tested and the stability of the implant documented. According to the trial implants the definite implant is assembled and implanted. After reduction of the implant the subscapularis tendon is reattached to the humerus using transosseous sutures. Regular closure of the incision is performed. After-care: Immediately post operatively a anteroposterior radiograph is performed. For the first two post-operative weeks the arm is immobilised in a sling and external rotation is allowed until 0° and flexion until 90° in internal rotation. Thereafter gradual increase of active mobility is allowed until the weeks post operatively, when full load bearing of the arm is allowed. Regular followup visits include a constant score, quick dash-score and conventional radiographic status(anteroposterior lateral and axillary view) and are performed to be post-operative 3 months 6 months 1 year and 18 months post operatively.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Implantation of the hemiverse shoulderprothesis
Landkrankenhaus Salzburg
Salzburg, Austria
Safety of implantation of the Hemi verse shoulder prosthesis
Adverse Events like fracute, infection, hematoma, nerve demage will be summarized, all clinical data will be evaluated
Time frame: Assessments will take place at day 7,
Safety of implantation of the Hemi verse shoulder prosthesis
Adverse Events like fracture, dislocation, infection, hematoma, pulmonary embolism, nerve demage will be summarized, all clinical data will be evaluated
Time frame: Assessments will take place at 6 weeks
Safety of implantation of the Hemi verse shoulder prosthesis
Adverse events such as infection stiffness, dislocation, fracture requiring any modification of the expected course and treatment will bed reported at three months.
Time frame: Assessments will take place at 3 months
Safety of implantation of the Hemi verse shoulder prosthesis
Adverse Events will be summarized, all clinical data will be evaluated
Time frame: Assessments will take place at 6 months
Safety of implantation of the Hemi verse shoulder prosthesis
Adverse Events will be summarized, all clinical data will be evaluated
Time frame: Assessments will take place at 12 months
change of pain using a visual analogue scale: 0-100, 0=no pain 100=maximal imaginable pain
highest pain level within last 25 hours will be recorded on a visual analogue scale
Time frame: assessment at 6 weeks, 3 months, 6 months and 12 months
change of active range of motion
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
active range of motion of the patient will be measured using a handheld goniometer for active elevation, abduction, external rotation and internal rotation
Time frame: assessment at 6 weeks, 3 months, 6 months and 12 months
change of strength of abduction
isometric strength of abduction will be measured at 90 degrees scapular abduction using a validated device starting at 3 months postoperatively until end of study
Time frame: assessment at 6 weeks, 3 months, 6 months and 12 months