To investigate the efficacy, safety and utility of hybrid closed-loop glucose control during a low carbohydrate vs. iso-energetic balanced diet in individuals with type 1 diabetes.
Closed-loop systems combining an insulin pump, a glucose sensor and a dosing algorithm that adjusts insulin delivery in a glucose-responsive manner achieve significantly better glucose control than conventional therapy in type 1 diabetes. Achieving satisfactory postprandial glucose control, however, continues to be challenging. The main limitation is the delayed pharmacokinetics and -dynamics of subcutaneously administered insulin with peak actions between 1 and 2 hours. Conversely, glucose levels typically rise within 10minutes following carbohydrate intake. This mismatch largely explains the inability of current closed-loop systems to control postprandial glucose excursions and the increased risk of late postprandial hypoglycaemia in response to both user-derived meal bolus administration and reactive algorithm-driven insulin infusion. Restricting carbohydrate may therefore significantly improve post-prandial glucose control whilst reducing hypoglycaemia. The efficacy of hybrid closed-loop operation in individuals with type 1 diabetes adhering to a low carbohydrate compared to a iso-caloric balanced diet has not been investigated to date.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
The study intervention will be an eucaloric low carbohydrate diet (15-20 % of carbohydrates) for 2 weeks.
The control intervention will be a energy-matched balanced diet (50 % of carbohydrates) for 2 weeks.
University Department of Endocrinology, Diabetology, Clinical Nutrition and Metabolism
Bern, Switzerland
Percentage of time in target glucose range (3.9 - 10.0 mmol/L)
The percentage of time in target glucose range will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Percentage of time above target (>10 mmol/L)
The percentage of time below target (\>10 mmol/L) will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Percentage of time below target (<3.9 mmol/L)
The percentage of time below target (\<3.9 mmol/L) will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Percentage of time in hypoglycemia (<3.0 mmol/L)
The percentage of time in hypoglycemia (\<3.0 mmol/L) will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Hypoglycemia burden quantified as the area under the curve (AUC) with glucose < 3 mmol/L
Hypoglycemia burden will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Percentage of time in hyperglycemia (>16.7 mmol/L)
The percentage of time in hyperglycemia (\>16.7 mmol/L) will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Mean glucose levels (mmol/l)
Mean sensor glucose levels will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Total daily insulin dose (U)
Total daily insulin dose will be recorded by the insulin pump
Time frame: 2 weeks
Daily manual bolus Insulin dose (U)
Daily manual bolus insulin dose will be recorded by the insulin pump
Time frame: 2 weeks
2 hour postprandial glucose increment (mmol/)
2 hour postprandial glucose increment will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Within-day standard deviation of glucose (mmol/l)
Within-day standard deviation of glucose will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Within day coefficient of variation of glucose (%)
Within day coefficient of variation of glucose will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Between days coefficient of variation of glucose (%)
Between days coefficient of variation of glucose will be assessed using continuous glucose monitoring (CGM).
Time frame: 2 weeks
Night-time percentage of time in target glucose range (3.9 - 10.0 mmol/L)
Percentage of time in target glucose range will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Night-time percentage of time above target (> 10.0 mmol/L)
Percentage of time above target will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Night-time percentage of time below target (< 3.9 mmol/L)
Percentage of time below target will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Night-time percentage of time in hypoglycemia (< 3.0 mmol/L)
Percentage of time in hypoglycemia will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Night-time percentage of time in hyperglycemia (> 16.7 mmol/L)
Percentage of time in hyperglycemia will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Night-time mean glucose levels
Mean sensor glucose levels will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Within night-time standard deviation of glucose (mmol/l)compared to within daytime period (06: - 24:00) standard deviation of glucose (mmol/l)
Standard deviation of glucose will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Within nighttime coefficient of variation of glucose(%)
Coefficient of variation of glucose (%) will be assessed using continuous glucose monitoring (CGM).
Time frame: Between 00:00-06:00 over 2 weeks
Change from baseline in lipid profile
Plasma Lipid profile (total Cholesterol, LDL-Cholesterol, HDL-Cholesterol, Triglycerides)
Time frame: 2 weeks
Total daily calorie intake (kcal/day)
Total daily calorie intake will be assessed based on photo-documentation of dietary intake
Time frame: 2 weeks
Mean beta-hydroxy butyrate level
based on download of blood Ketone meter
Time frame: 2 weeks
Change from baseline in fasting plasma metabolome
Fasting serum sampling
Time frame: 2 weeks
Incidence of (serious) adverse events
Incidence of severe hypoglycaemia, signficant hyperglycaemia with ketonemia, other SAEs, adverse events, adverse defice effects and device deficiencies
Time frame: 12 weeks
Percentage of time when pump was in Auto-mode
Based on pump data download
Time frame: 2 weeks