Physioflow® is a new device for measuring cardiac output in a non-invasive way using a thoracic bioimpedance technique. This technique has been validated in patients in stress tests as well as in Chronic Obstructive Pulmonary Disease (COPD) patients, in obese patients and in children. Very little work has been published in intensive care unit (ICU) and no studies have been done on hemodynamically unstable patients. The aim of this work is to compare the cardiac output measured by Physioflow® to the transthoracic echocardiography (TTE) in ventilated, sedated patients hospitalized in ICU receiving catecholamines and for whom the attending physician wants to evaluate the fluid responsiveness using the TTE and a passive leg raising maneuver (PLR).
All patients included will be simultaneously monitored with TTE and the Physioflow® thoracic electrical bioimpedance device. Cardiac output is measured by the Physioflow® Thoracic Bioimpedance Device and TTE before and after PLR. If the attending physician decide to administer fluid expansion a new set of cardiac output measurement will be performed before and after the volume expansion.
Study Type
OBSERVATIONAL
Enrollment
1
All patients included will be simultaneously monitored with transthoracic echocardiography (TTE) and the Physioflow® thoracic electrical bioimpedance device. Cardiac output is measured by the Physioflow® Thoracic Bioimpedance Device and TTE before and after passive leg raising maneuver (PLR)
All patients included will be simultaneously monitored with transthoracic echocardiography (TTE) and the Physioflow® thoracic electrical bioimpedance device. Cardiac output is measured by the Physioflow® Thoracic Bioimpedance Device and TTE before and after passive leg raising maneuver (PLR)
CHU Amiens
Amiens, France
Measure of cardiac output with transthoracic echocardiography (TTE) before PLR
Measure of Cardiac output with transthoracic echocardiography (TTE) before passive leg raising maneuver (PLR)
Time frame: during one hour , the day of inclusion
Measure of Cardiac output with Physioflow before PLR
Measure of Cardiac output with Physioflow before passive leg raising maneuver (PLR)
Time frame: during one hour , the day of inclusion
Measure of cardiac output with transthoracic echocardiography (TTE) after PLR
Measure of cardiac output with transthoracic echocardiography (TTE) after passive leg raising maneuver (PLR)
Time frame: during one hour , the day of inclusion
Measure of cardiac output with Physioflow after PLR
Measure of cardiac output with Physioflow after passive leg raising maneuver (PLR)
Time frame: during one hour , the day of inclusion
Measure of cardiac output with transthoracic echocardiography (TTE) after volume expansion
Measure of cardiac output with transthoracic echocardiography (TTE) after volume expansion
Time frame: during one hour , the day of inclusion
Measure of cardiac output with Physioflow after volume expansion
Measure of cardiac output with Physioflow after volume expansion
Time frame: during one hour , the day of inclusion