Peri-implant mucositis is an important disease entity as a result of its high prevalence and the lack of a standard mode of therapy. Non-surgical therapy of peri-implant mucositis appears to be partially effective in resolving the disease. In several cases, however, only limited improvements have been reported in the main clinical parameters (bleeding partial resolution and presence of pocket at follow-up visits) and there is a clear tendency to relapse of the disease. In these cases it is therefore recommended to consider adjunctive therapies. Numerous approaches have been used for implant surface decontamination including mechanical, chemical and treatments by means of air-powder or laser. The aim of the present randomized controlled clinical trial will be to assess the efficacy in improving clinical parameters of two further methods of implant surface decontamination (Er:YAG laser or air-abrasive device) after mechanical cleaning during non surgical treatment of peri-implant mucositis.
Peri-implant mucositis, defined as an inflammatory lesion of the surrounding peri-implant tissues without loss of supporting bone, is an important disease entity as a result of its high prevalence and the lack of a standard mode of therapy. Although the current epidemiological data are limited, peri-implant mucositis affects 43% of the subjects. Numerous approaches have been used for implant surface decontamination, including mechanical, chemical and laser treatments. Using conventional mechanical means, eradication of pathogens on implant surfaces with threads and often with rough surface structures is difficult. Treatment models, such as debridement, effectively used to treat teeth with periodontitis, cannot be used in the same way on rough threaded implant surfaces. The implant rough surface structure also provides the bacteria with ''protected areas'', inaccessible to conventional mechanical removal. A treatment protocol that may offer an advantage over traditional mechanical treatment includes the use of laser therapy. Data have shown that treatments with Er:YAG lasers have a bactericidal effect. Er:YAG laser treatment can debride the implant surface effectively and safely. Slightly better clinical results in terms of bleeding on probing and clinical attachment level have been reported by Er:YAG laser treatment as compared with traditional non-surgical mechanical debridement with curettes and chlorhexidine. The air abrasive method for the removal of bacterial plaque on tooth surfaces has also been used in the treatment of mucositis, demonstrating no relevant adverse effects. Until recently, air-polishing devices have used a slurry of water and sodium bicarbonate (NaHCO3) and pressurized air/water. A less abrasive method using an aminoacid glycine has been proven to be effective in removing bacterial biofilm structures in deep periodontal pockets and safe by not causing emphysema. Moreover the use of a glycine-based powder does not seem to cause titanium implant surface changes. The aim of the present randomized controlled clinical trial will be to assess the efficacy in improving clinical parameters of two further methods of implant surface decontamination (Er:YAG laser or air-abrasive device) after mechanical cleaning during non surgical treatment of mucositis.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
75
mechanical debridement: Inflammatory tissue, excess cement or plaque deposits will be removed using hand instruments
mechanical debridement: Inflammatory tissue, excess cement or plaque deposits will be removed using hand instruments. Furthermore, an Er:YAG laser will be used for the implant surface decontamination.
mechanical debridement: Inflammatory tissue, excess cement or plaque deposits will be removed using hand instruments. Furthermore, an Air-Powder treatment will be provided on the implant/abutment surface.
Università Vita-Salute San Raffaele
Milan, Italy
Bleeding on probing changes
changes of bleeding on probing, evaluated as present if bleeding will be evident within 30 s after probing, or absent, if no bleeding will be noticed within 30 s after probing
Time frame: baseline, 1, 3, 6 months
probing pocket depth changes
changes in probing pocket depth, measured from the mucosal margin to the bottom of the probable pocket
Time frame: baseline, 1, 3, 6 months
mucosal recession changes
changes in mucosal recession, measured from the mucosal margin to the restoration margin or implant neck
Time frame: baseline, 1, 3, 6 months
clinical attachment level changes
changes in clinical attachment level, measured from the restoration margin or implant neck to the bottom of the probable pocket at six aspects per implant (mesio-vestibular, mid-vestibular, disto-vestibular, mesio-oral, mid-oral, and disto-oral.
Time frame: baseline, 1, 3, 6 months
complete disease resolution (percentage)
At the implant level, the level of disease resolution was defined as complete when BoP was = 0 out of six sites per implant
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.