Comparison of the capsular bag performance of the RayOne Hydrophobic Aspheric with the RayOne Aspheric
Cataract surgery is nowadays considered a safe surgery with a short rehabilitation time for the patients. Two main problems arising post-surgically are the predictability and stability of the implanted intraocular lens (IOL) in the capsular back and the formation of posterior capsule opacification (PCO). The performance of the IOL in the capsular bag influences the anterior chamber depth (ACD), tilt and decentration of the IOL, as well as formation of PCO. The main source of error for calculation of IOL power is an inaccurate prediction of the post-surgical ACD resulting in short- or farsightedness. Furthermore, capsular fibrosis and phimosis can also lead to tilt and decentration of the intraocular lens. PCO is one of the most frequent long-term complications after cataract surgery, occuring in about 12% after 1 year, in 21% after 3 years, and in 28% after 5 years post-surgically. PCO arises when lens epithelial cells (LECs) migrate and proliferate, growing in between the IOL and the posterior capsule, leading to decreased visual acuity. Material and design of the IOL may have an effect on the formation of PCO. It is suggested that 360° square edge design and hydrophobic material of the IOL may help in the prevention of PCO. Hence, the aim of this study is to evaluate the capsular bag performance of monofocal IOLs with different materials but similar design and their influence on PCO formation. 100 eyes of 50 patients will be included into this study. After randomization one eye is implanted with the hydrophilic IOL, whereas the other eye gets the aspherical IOL. Follow-up visits will be 1 - 2 hours and 1 week after the surgery, as well as 6 months, 12 months, and 24 months post-surgically. During this visit a slit lamp examination, measurement of the intraocular pressure, visual acuity assessment, biometrical measurements of the eye, retroillumination photography and analysis of tilt and decentration of the IOL using the purkinjemeter will be performed.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
RayOne Hydrophobic Aspheric, hydrophobic IOL
RayOne Aspheric, non-hydrophobic IOL
Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
Vienna, Austria
Anterior chamber depth (ACD)
The change in anterior chamber depth (ACD) before and after surgery will be measured using the IOL Master 700 and compared between the two different IOLs
Time frame: 24 months
Distance visual acuity
Uncorrected and corrected distance visual acuity will be determined using ETDRS-charts in a distance of 4 meters and differences in refraction will be compared between the two IOLs
Time frame: 24 months
Intraocular pressure
Intraocular pressure will be measured before and after surgery using non-contact-tonometry and differences will be compared between the two differen IOLs
Time frame: 24 months