The objective of this study is to evaluate angiographic confirmation of placement of any guidewire beyond the CTO, in the true vessel lumen, in patients undergoing CTO percutaneous coronary intervention (PCI) in which at least one Teleflex guidewire and at least one Turnpike catheter are used.
A prospective, multicenter, single-arm, intent-to-treat, literature-controlled clinical study. The study will be conducted in up to 15 investigational sites in the U.S. This study will enroll up to 150 patients to provide adequate powering for hypothesis testing and an evaluable sample size of at least 135 patients. The population for this study is participants with signs and/or symptoms considered typical of ischemic heart disease attributed to a de novo CTO in a native coronary artery who are suitable candidates for a percutaneous revascularization. Study devices include the GuideLiner® V3 catheter, TrapLiner® catheter, Turnpike® catheter, and a series of five coronary guidewires (SpectreTM guidewire, R350TM guidewire, RaiderTM guidewire, WarriorTM guidewire, and BanditTM guidewire). All study devices are currently 510(k) cleared for non-CTO indications. * GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional devices, and to assist in crossing de novo chronic total occlusions (CTO). * The TrapLiner catheter is intended for use in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, to facilitate placement of interventional devices, to facilitate the exchange of an interventional device while maintaining the position of a guidewire within the vasculature, and to assist in crossing de novo chronic total occlusions (CTO). * The Turnpike catheters are intended to be used to access discrete regions of the coronary and/or peripheral vasculature. They may be used to facilitate placement and exchange of guidewires, to subselectively infuse/deliver diagnostic and therapeutic agents, and to assist in crossing de novo coronary chronic total occlusions (CTO). The Teleflex guidewires are intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature, including use in crossing or assisting in crossing de novo coronary chronic total occlusions (CTO).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
150
Teleflex's series of study guidewires and catheters will be used to facilitate the safe and effective crossing of de novo CTOs and placement of conventional guidewires beyond the lesion via either a true lumen or subintimal pathway.
GuideLiner® V3 catheter, TrapLiner® catheter, Turnpike® catheter
Torrance Memorial Medical Center
Torrance, California, United States
Piedmont Heart Institute
Atlanta, Georgia, United States
Emory University
Atlanta, Georgia, United States
Number of Participants With Procedure Success
Defined as angiographic visualization of any guidewire in a position either distal or proximal to the occlusion depending on the route of access and the absence of in-hospital major adverse cardiac events (MACE). • MACE defined as any serious adverse experience that includes cardiac death, target lesion revascularization, or post-procedural myocardial infarction (MI) (Q-wave or non-Q-wave, with creatine kinase (CK) with Muscle (M)-Brain (B) subunits \> 3 ULN).
Time frame: Through Discharge up to 24 hours post-procedure
Number of Participants With Successful Recanalization.
Defined as angiographic confirmation of crossing the chronic total occlusion and restoring blood flow to the affected area.
Time frame: Through Procedure, up to 4 hours
Number of Participants With In-hospital MACE.
Defined as any serious adverse experience that includes cardiac death, target lesion revascularization, or post-procedural MI (Q-wave or non-Q-wave, with CK-MB \> 3 ULN). The components of MACE will also be reported separately.
Time frame: Through Discharge up to 24 hours
Number of Participants With Clinically Significant Perforation.
Defined as any perforation resulting in hemodynamic instability and/or requiring intervention including pericardiocentesis, embolization, prolonged balloon occlusion, stent graft, or comparable therapy.
Time frame: Through Procedure up to 4 hours
Number of Participants With Procedural Success According to Crossing Technique.
Procedural success is defined as angiographic visualization of any guidewire in a position either distal or proximal to the occlusion depending on the route of access and the absence of in-hospital major adverse cardiac events (MACE).
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Brigham and Women's Hospital
Boston, Massachusetts, United States
Massachusetts General Hospital
Boston, Massachusetts, United States
Beth Israel Deaconess Medical Center
Boston, Massachusetts, United States
Henry Ford Hospital
Detroit, Michigan, United States
Minneapolis Heart Institute Foundation
Minneapolis, Minnesota, United States
Missouri Cardiovascular Specialists
Columbia, Missouri, United States
NYU Langone Health
New York, New York, United States
...and 3 more locations
Time frame: Through Procedure up to 4 hours post-procedure
Number of Participants With Technical Success.
Defined as successful guidewire recanalization is applicable to investigational devices as at least one investigational guidewire must be used in every procedure.
Time frame: Through Procedure up to 4 hours post-procedure