This study aims to assess whether the acceptable image quality is achievable using low monoenergetic imaging of dual-energy CT with deep learning-based denoising, and low contrast media dose calculated based on lean body weight for the detection of hepatocellular carcinoma.
The use of iodinated contrast media in CT is associated with an immediate hypersensitivity reaction in a dose-dependent manner. Therefore, it is important to reduce the contrast dose for CT exams in patients who are required repeated CT examinations, including patients with hepatocellular carcinoma (HCC). Low monoenergetic images of dual-energy CT can provide higher iodine contrast than conventional images, thus enabling reduction of contrast media. The high image noise in low monoenergetic images may be improved by using model-based IR techniques and deep learning-based denoising (DLD) algorithms. Besides, lean body weight (LBW)-based contrast dose determination can be another option to reduce contrast media dose compared with total body weight-based dose determination since the volumes of blood and liver are not strictly proportional to total body weight. Therefore, we surmised that 50 keV images reconstructed with DLD algorithms with reducing iodine load by 30% based on LBW could produce the comparable image quality and lesion conspicuity compared with standard iodine-dose 120kVp images. In this single-center prospective, randomized clinical trial, we aimed to investigate the effectiveness of low-contrast dose CT using 50 keV and DLD technique compared with the standard contrast-dose protocol using model-based IR in patients at high risk of HCC.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
90
CT contrast media (iobitridol 350mgI/kg) is administrated at a dose of 450mgI/kg based on lean body weight.
CT contrast media (iobitridol 350mgI/kg) is administrated at a dose of 560mgI/kg based on total body weight.
Seoul National University Hospital
Seoul, South Korea
HCC conspicuity
qualitative scoring for focal lesion depiction on four-point scale (1: worst, 4: excellent, representative value is average score)
Time frame: 6 months after complete enrollment
Image noise
qualitative scoring for image noise on four-point scale (1: worst, 4: excellent, representative value is average score)
Time frame: 12 months after complete enrollment
Image contrast
qualitative scoring for image contrast on four-point scale (1: worst, 4: excellent, representative value is average score)
Time frame: 12 months after complete enrollment
Overall image quality
qualitative scoring for image quality on four-point scale (1: worst, 4: excellent, representative value is average score)
Time frame: 6 months after complete enrollment
Lesion detection
assessment of focal liver lesion (HCC) on CT according to Liver Imaging Reporting and Data System (LI-RADS)
Time frame: 12 months after complete enrollment
Hounsfield unit
measurement of hounsfield unit in aorta, portal vein, liver parenchyma, and paraspinal muscles
Time frame: 3 months after complete enrollment
Contrast media dose
administered contrast media dose in each group
Time frame: 3 months after complete enrollment
Radiation dose
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
measured radiation dose in each group
Time frame: 3 months after complete enrollment