This randomized trial assessed the effect of modifying building envelop and level of air filtration on blood pressure over two hour exposure sessions.
Living close to major roadways is associated with elevated blood pressure (BP) amongst other adverse health effects. There is growing evidence that ultrafine particles (UFP, \<100 nm in diameter), which are elevated near major roads and highways, contribute to such risks. We assessed the efficacy of high efficiency particulate arrestance (HEPA) filtration and building envelope adjustment at reducing exposure to and health effects of air pollution next to major highways. We used a randomized three-period crossover trial design to assign 77 participants (aged 40-75 and without diagnosis of hypertension) to three two-hour exposure sessions. Sessions were conducted in one of two rooms immediately adjacent to highways. High, medium and low exposures were attained by varying the degree of air exchange and amount of HEPA filtration in the room. During high exposure sessions, the room was ventilated with outdoor air and no filtration was used. During low exposure sessions, leakage of outdoor air into the room was minimized and HEPA filtration was maximized. During medium exposure sessions, a moderate amount of HEPA filtration was used (less than half of that used in low sessions). Indoor particle number and black carbon (BC) concentrations (i.e., markers of traffic-related air pollution) were monitored continuously. During each session participants sat quietly and wore noise-cancelling headphones, while their BP was monitored every ten minutes using an ambulatory BP monitor. We monitored pulse and oxygen saturation continuously.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
77
Air filters and closing and sealing of windows and doors was used to reduce infiltration of air pollution from outdoors in rooms next to major highways at rush hour.
University of Connecticut
Farmington, Connecticut, United States
Systolic Blood Pressure (SBP)
Systolic blood pressure measured with ambulatory blood pressure monitors in mmHg.
Time frame: Over 2 hour exposure period, we measured SBP after 20 minutes with the objective to assess change in SBP in a time series of measurements over that time period.
Diastolic Blood Pressure (DBP)
The unit of measurement, mmHg for the diastolic blood pressure.
Time frame: Over a 2 hour exposure period with the objective to assess change in DBP measured after 10 minutes in a time series of measurements over that time period.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.