In this study, the investigators compared mechanical and manual chest compressions in out-of-hospital cardiac arrest cases.
In this study, the investigators retrospectively analyzed resuscitations performed over a 2-year period and compared manual and mechanical chest compressions in terms of return of spontaneous circulation, 30-day survival, and hospital discharge parameters.
Study Type
OBSERVATIONAL
Enrollment
214
LUCAS is a portable device designed to rule out the problems encountered during manual chest compression, capable of performing standard and continuous chest compressions at a depth of 4-5 cm and at least 100 times per minute.
In this way chest compressions will be handled by humans themselves.
Ankara Yıldırım Beyazıt University, School of Medicine, Department of Emergency Medicine
Ankara, Çankaya, Turkey (Türkiye)
Rate of the mortality on the 30th day
Mortality from the admission to the 30th day
Time frame: 30 days
Rate of the return of spontaneous circulation
Return of spontaneous circulation at least 5 minutes
Time frame: 5 minutes