The conventional standard-dose scanner leads to a significantly greater X-ray exposure than the standard X-ray. Recently, technological innovations like the ULD ("Ultra Low Dose") scanner have been developed to reduce the dose of X-rays delivered to the patient. The general purpose of this study is to validate the ULD scanner in case of emergency trauma of the dorsolumbar spine, pelvis and / or extremities.
The main purpose of this study is to compare the diagnostic performances of the ULD scanner with those of the standard X-ray when looking for fractures of the dorsolumbar region, the pelvis, proximal femur or the extremities, in an emergency situation in adults, once the diagnosis of fracture has been ascertained by the classical standard-dose scanner (gold standard). The statistical analyses will be performed with the help version 9.4 or subsequent versions of SAS software (SAS Institute, Cary, NC, USA) and/or version 3.5.1 or subsequent versions of R software (R Development Core Team (2018). R Foundation for Statistical Computing, Vienna, Austria). The secondary objectives of this study are to: A. Compare the diagnostic performances of the two examination methods under study (ULD scan vs. standard X-ray) in the search for bone structure anomalies, damage to the soft tissues, damage to the joints and/or discopathies at the site(s) involved. B. Compare the diagnostic performances of the two examination methods under study) (ULD scan vs. standard X-ray) in the search for fractures of the site involved. C. Evaluate the diagnostic agreement between two readers (senior radiologist and junior radiologist) for each of the two examination methods under study (ULD scan vs. standard X-ray). D. Compare the radiologist's self-declared impression of each of the two examination methods under study (ULD scan vs. standard X-ray) in terms of subjective quality: overall image quality, diagnostic quality of the examination method and the level of confidence in the diagnosis made, overall and for each of the two readers (senior and junior). E. Compare the doses of X-rays administered for each of the two examination methods under study (ULD scan vs. standard X-ray). F. Compare the interpretation time for each examination method under study (ULD scan vs. standard X-ray), globally and for each of the two readers (senior and junior). For the evaluation of the diagnostic performances (main objective and secondary objectives A et B), only the senior radiologist's interpretation will be considered.
Study Type
OBSERVATIONAL
Enrollment
554
The following doses will be applied: 6 mGy.cm for the extremities 50 mGy.cm for the dorsal spine 130 mGy.cm for the lumbar spine 130 mGy.cm for the pelvis
The following doses will be applied: For the pelvis : front view and profile for the hip. For the dorsal spine : front and profile. For the lumbar spine : front and profile For the extremities : front and profile
The following doses will be applied: 6 mGy.cm for the extremities 50 mGy.cm for the dorsal spine 130 mGy.cm for the lumbar spine 130 mGy.cm for the pelvis
Centre Hospitalier Universitaire
Nîmes, Gard, France
Clinique de l'Union
Saint-Jean, Haute-Garonne, France
Clinique du Parc
Castelnau-le-Lez, Hérault, France
Centre Hospitalier de Mont-de-Marsan
Mont-de-Marsan, Nouvelle-Aquitaine, France
Menouer TALEB
Alès, France
Presence of at least one fracture in the dorsal spine evaluated with a classical, standard-dose scan (Gold standard)
YES/NO
Time frame: Day 0
Presence of at least one fracture in the lumbar spine evaluated with a classical, standard-dose scan (Gold standard)
YES/NO
Time frame: Day 0
Presence of at least one fracture of the pelvis and proximal femurs evaluated with a classical, standard-dose scan (Gold standard)
YES/NO
Time frame: Day 0
Presence of at least one fracture of the hands / wrists evaluated with a classical, standard-dose scan (Gold standard)
YES/NO
Time frame: Day 0
Presence of at least one fracture of the feet /ankles evaluated with a classical, standard-dose scan (Gold standard)
YES/NO
Time frame: Day 0
Presence of at least one fracture in the dorsal spine evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of at least one fracture in the lumbar spine evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of at least one fracture in the pelvis and proximal femurs evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of at least one fracture of the hands / wrists evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of at least one fracture of the feet /ankles evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of at least one fracture of the dorsal spine evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of at least one fracture of the lumbar spine evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of at least one fracture of the pelvis and proximal femurs evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of at least one fracture of the hands / wrists evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of at least one fracture of the feet /ankles evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of an abnormality of the bone structure at the anatomic site(s) concerned evaluated with a classical Gold Standard scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the soft tissues at the anatomic site(s) concerned evaluated with a classical Gold Standard scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the joints at the anatomic site(s) concerned evaluated with a classical Gold Standard scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the invertebral discs at the anatomic site(s) concerned evaluated with a classical Gold Standard scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the bone structure at the anatomic site(s) concerned evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the soft tissues at the anatomic site(s) concerned evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the joints at the anatomic site(s) concerned evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the invertebral discs at the anatomic site(s) concerned evaluated with a ULD scan
YES/NO
Time frame: Day 0
Presence of an abnormality of the bone structure at the anatomic site(s) concerned evaluated with a standard X-ray
YES/NO
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Day 0
Presence of an abnormality of the soft tissues at the anatomic site(s) concerned evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of an abnormality of the joints at the anatomic site(s) concerned evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Presence of an abnormality of the intervertebral discs at the anatomic concerned site(s) evaluated with a standard X-ray
YES/NO
Time frame: Day 0
Image quality of the ULD scanner and standard X-ray
By means of a 4-point Likert scale, both the senior and junior radiologists can give their subjective impression of the overall image quality of each of the two examination methods under study (ULD scan vs. standard X-ray) by saying how much they agree or disagree that the overall quality of the image is good enough to detect a fracture. On the Lickert scale, 1- Uninterpretable, 2- Interpretable in spite of a slight technical problem (centering, movement, constant), 3-Completely interpretable in spite of a slight technical problem. 4- No technical problem.
Time frame: Day 0
Diagnostic quality of the ULD scanner and standard X-ray
Using a 5-point Lickert scale (in which 1= Inacceptable, 2 = Sub-optimal, 3 = Acceptable, 4 = Above average, 5- Excellent) both the senior and junior radiologists will give their subjective impression of the overall diagnostic quality of each of the two examination methods under study (ULD scan vs. standard X-ray).
Time frame: Day 0
Confidence level of the ULD scanner and standard X-ray
Using a 5-point Lickert scale (1- Very poor, 2- Poor, 3- Fair, 4- Good, 5- Excellent) both the senior and junior radiologists will give their subjective impression of their overall level of confidence in the diagnosis made for each of the two examination methods under study (ULD scan vs. standard X-ray).
Time frame: Day 0
Effective dose for each exam with the ULD scanner
No. of millisieverts (mSv)
Time frame: Day 0
Effective dose for each exam with the standard X-ray
No. of millisieverts (mSv)
Time frame: Day 0
Interpretation time for each exam with the ULD scanner
Measured in minutes
Time frame: Day 0
Interpretation time for each exam with the standard X-ray
Measured in minutes
Time frame: Day 0