Prospective, single-arm, open label, multicentre, phase II pilot study to evaluate the immediate and short term (one month) impact of a new long acting double bronchodilator on innovative parameters in stable and moderate to severe COPD patients. * Variability and complexity of resting tidal breathing * Oscillatory resistance and reactance of airways Tidal volume variability and complexity is decreased in airway obstruction and is expected to improve with a bronchodilator treatment, together with lung mechanics. The relationship with changes in dyspnea and conventional pulmonary function tests is the second aim of study. After baseline assessment of these parameters, clinical and lung function evaluation will be performed 2 hours post-drug (peak drug effects). Patients will continue treatment with PT003 for 4 weeks. On Day 30, the same clinical and lung function assessments will be performed pre (trough) and 2h-post dose in order to obtain after-treatment measurements.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
4
Formoterol-glycopyrronium co suspension (PT003) in a Metered Dose Inhaler, 2 puffs twice daily
Hop Calmette Chu Lille
Lille, France
Analysis of tidal volume (VT) complexity (noise limit as main parameter )
Comparison of the noise limit between V2 baseline (pre-treatment) and V3 peak (2 hours +/- 30 min post dose). Noise limit is a mathematical treatment of tidal breathing signal evaluating its complexity and no other description can be provided
Time frame: at 1 month
change of frequency-tidal volume pattern
the inspiratory time (Ti, measured in second) , the expiratory time (Te,measured in second) and the respiratory frequency
Time frame: Baseline, at 1 month
Tidal volume Largest Lyapunov component (an indicator of the sensitivity of the system to initial conditions)
Time frame: Baseline, at 1 month
change of resistance at 5Hz , at 20 Hz
The fundamental principle of forced oscillometry is that lung function can be assessed by measuring changes in pressure and flow in response to external pressure applied at the airway opening. Resistance is complex measure that incorporates the lack of changes in pressure and volume and the rate of these changes in response to pressure oscillations at a specific frequency. All these measurements are expressed in the same unit (for resistance and reactance) and refer to oscillatory mechanics obtained by the same device. AX and resonant frequency are correlated to reactance.
Time frame: Baseline, at 1 month
Change of reactance
the fundamental principle of forced oscillometry is that lung function can be assessed by measuring changes in pressure and flow in response to external pressure applied at the airway opening. Reactance is complex measure that incorporates the changes in pressure and volume and the rate of these changes in response to pressure oscillations at a specific frequency at 5Hz was used. Reactance is thought to reflect the elastic properties of the lung. All these measurements are expressed in the same unit (for resistance and reactance) and refer to oscillatory mechanics obtained by the same device.
Time frame: Baseline, at 1 month
Change of AX and resonant frequency
Area under reactance curve (AX) and resonant frequency are correlated to reactance.
Time frame: Baseline, at 1 month
change of spirometry parameters
Spirometry : FEV1, FVC, FEV1/FVC
Time frame: at 1 month
change in lung function as assessed through body plethysmography
Change from baseline to end of treatment in the following measures Total lung capacity (TLC) Residual volume (RV) Inspiratory capacity (IC) Functional residual capacity (FRC) All plethysmographic parameters shown here are lung volumes, expressed in liters, and are somewhat interrelated. For instance IC is TLC- FRC.There is no reason to separate these outcome measures
Time frame: Baseline, at 1 month
change of airway resistance (RAW) and specific airway conductance (sGAW).
sGaw is specific conductance, ie 1/resistance divided by the volume at which resistance was measured. These two parameters are always measured and used together. All plethysmographic parameters shown here are lung volumes, expressed in liters, and are somewhat interrelated.
Time frame: Baseline, at 1 month
Visual Analogic Scale
Two VAS (± 100 mm ) will be used to evaluate changes (much worse-unchanged-much better) in dyspnea and chest tightness 2 hours after PT003 administration and at 4 weeks in through and post dose conditions
Time frame: Baseline, at 1 month
Likert scales
Likert scales (7 points) will assess changes in dyspnea and global health at visit 3 in comparison with pre treatment condition (V2).
Time frame: Baseline, at 1 month
BDI/TDI
The BDI/TDI is an instrument developed to provide a multidimensional measure of dyspnea in relation to activities of daily living. The Baseline Dyspnea Index (BDI) provides a measure of dyspnea at a single state, the baseline, and the Transitional Dyspnea Index (TDI) evaluates changes in dyspnea from the baseline state. The instrument consists of three components: functional impairment, magnitude of task, and magnitude of effort. For the BDI, each of these three components are rated in five grades from 0 (severe) to 4 (unimpaired), and are summed to form a baseline total score from 0 to 12. For the TDI, changes in dyspnea are rated for each component by seven grades from -3 (major deterioration) to +3 (major improvement), and are added to form a total TDI score from -9 to +9. Positive scores indicate an improvement, and a change from the BDI or a difference between treatments of 1 point has been estimated to constitute the minimum clinically important difference (MC
Time frame: Baseline, at 1 month
mMRC dyspnea scale
The Modified Medical Research Council (mMRC) dyspnea scale uses a simple grading system to assess a subject's level of dyspnea that consists of five statements about perceived breathlessness. It is an interviewer-administered ordinal scale on which subjects provide their dyspnea according to five grades of increasing severity (scores ranges from 0 (none) to 4 (very severe).
Time frame: Baseline, at 1 month
Modified Dyspnea Profile (MDP)
The MDP consists of 11 items evaluating both the sensory and affective dimensions of dyspnoea. One item (A1) assesses the unpleasantness of dyspnoea on a 0-10 visual numerical scale anchored by "neutral" (0) and "unbearable" (10). Five items assess the sensory dimension of dyspnoea, both in terms of quality and intensity (on a scale of 0-10). Five items assess the affective dimension of dyspnoea, also in terms of quality and intensity (on a scale of 0-10).
Time frame: Baseline, at 1 month
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.