This study evaluates the safety and efficacy of high tidal volumes generated by "Adapted Support Ventilation (ASV) mode' in mechanically ventilated severe COPD patients. Every patient will be ventilated consecutively with ASV and Volume Control (VC) modes at 2 different levels of minute volume in 2 sets. ASV mode is expected to be safe measured by adequate inspiratory transpulmonary pressures and expected to be as effective as VC mode with lower intrinsic positive end expiratory pressure (iPEEP) levels.
Acute exacerbations of Chronic Obstructive Pulmonary Disease (COPD) may require mechanical ventilation. Various mechanical ventilation strategies and modes can be used to manage respiratory insufficiency in such patients. High tidal volumes required for mechanical ventilation of patients with obstructive pathologies is a well-known fact. Adapted Support Ventilation (ASV) is an intelligent closed-loop mechanical ventilation mode which automatically adjusts ventilation to lung mechanics. Led by measured lung mechanics, ASV mode often generates higher than usual tidal volumes during mechanical ventilation of COPD patients, particularly if the minute volume (MV) target is high. Thus, the effects of high tidal volumes on inspiratory transpulmonary pressure (Ptp), and whether Ptp stays within safe limits during ASV mode is of great interest. Patients with acute exacerbation of COPD who required mechanical ventilation will be enrolled in the first 24 hours of admission to the intensive care unit. All patients will be deeply sedated. An esophageal balloon catheter will be inserted in order to measure transpulmonary pressure. 100 % minute volume target will be calculated in advance as 100 ml per ideal body weight. Patients will be ventilated with two different MV targets in two sets. 'Adapted support ventilation' and 'volume control (VC)' modes will be used consecutively within each set. While the target minute volume will be 100 % in the first set, the volume target in the second set will be tuned to decrease patients PaCO2 below 45 mmHg. The sequence of ventilation mode will be randomized within each set. Ventilation periods will be 30 minutes with 15 minutes washout period in between. İf Ptp increase above 20 cmH20 at any ventilation mode, the tidal volume will be decreased. ASV mode is expected to be safe, assessed by adequate inspiratory transpulmonary pressures, and expected to be as effective as VC mode with lower intrinsic positive end expiratory pressure (iPEEP) levels.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
DOUBLE
Enrollment
20
Patients will be ventilated to reach minute volume target of %100 (100 ml per ideal body weight).
Patients will be ventilated to reach minute volume target associated with PaCO2 less than 45%.
Izmir Dr. Suat Seren Chest Diseases and Surgery Education and Research Hospital, Intensive Care Unit
Izmir, Yenisehir, Turkey (Türkiye)
Transpulmonary inspiratory pressure (Ptinsp)
Ptpinsp will be measured with an inspiratory pause maneuver.
Time frame: 30'th minute of each intervention arm
Intrinsic Positive End Expiratory Pressure (PEEPi)
PEEPi will be measured with an expiratory hold maneuver.
Time frame: 30'th minute of each intervention arm
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.