Monocentric comparative before / after study to evaluate the efficacy of Safe Infusion Devices (SIDs) in reducing drug exposure to nurses compared to usual perfusion practices.
Despite the decreasing of environmental contamination throughout the anticancer drug circuit, the administration of chemotherapies remains at risk of occupational exposure for nurses. Many medical devices aim at securing administration, but none have been scientifically evaluated to verify the actual improvement. A monocentric comparative before / after study was carried out in an oncology day hospital in order to evaluate the efficacy of Safe Infusion Devices in reducing drug exposure compared to usual perfusion practices (neutral solvent-purged infusers). The rate of nurses' gloves contamination was estimated. The eligible protocols must contain at least one disconnection step and one of the 10 drugs screened. To avoid false negatives, each sample of gloves was contaminated with a drop of topotecan. Association between contamination and other variables was investigated using a multivariate regression analysis. The usual practice leaded to a rate of 58.3% of contaminated samples while Safe Infusion Devices to a rate of 15%: Safe Infusion Devices reduced the risk of gloves contamination by 84% in multivariate analysis (Odds ratio=0.16; 95% confidence interval=0.05-0.47; p\<0.001). Topotecan was identified within 100% of the samples. Only one case of cross-contamination has occurred. Despite the current practice of using neutral solvent-purged infusers, the occupational exposure remains high for nurses and Safe Infusion Devices significantly reduced this risk of exposure. However, glove contamination is only a surrogate endpoint. The results confirmed that the disconnection of empty bags resulted in occupational exposure. Except a contamination due to the leakage of a bag, no cross-contamination was detected. This validated the environmental quality of the cytotoxic drug circuit. Safe Infusion Devices were highly effective but did not completely eliminate exposure.
Study Type
OBSERVATIONAL
Enrollment
120
Safe infusion device is a different method than usual infusion practices (neutral solvent-purged infusers)
Institut de Cancérologie Lucien Neuwirth
Saint-Priest-en-Jarez, France
Rate of contamination of nurses' gloves with cytotoxic products
The statistical unit consists of a sample taken from all the gloves used for the administration of a daily course. The dosing assay allowed to identify a panel of 10 cytotoxic drugs (HPLC MS/MS).
Time frame: day 1
Quantitative contamination of nurses' gloves with cytotoxic products
The dosing assay allowed to identify a panel of 10 cytotoxic drugs (HPLC MS/MS).
Time frame: day 1
Costs
For each daily course performed in 2017 requiring the intravenous route, the necessary devices were estimated according to the two strategies
Time frame: day 1
Manufacturing time
The manufacturing time was defined as the time elapsed between the time of passage in the cleanroom and the end of manufacturing of the first drug of the course.
Time frame: day 1