Investigator team hypothesize that artifacts generated by the presence of an acoustic implant subjected to the magnetic field of the MRI are variable depending on the type of sequence and can be reduced by structural modifications of the implant and by variations in its appearance positioning with respect to the magnetic field MRI.
Little scientific data is available on the artifacts generated by hearing implants. Indeed, hearing rehabilitation for deaf people was given priority over the potential constraints of imaging. Investigator team find less than 10 articles with a search of following keywords on the pubmed database: Artifacts AND MRI AND cochlear implants. Only one of these articles deals with demagnetization. There is only one article dealing with artifacts with the Bonebridge implant. There are no studies with the Attract implant and a recent one with the new Synchrony mobile magnet implant, but by removing the magnet which implies a minimum response time and therefore not compatible with emergency care. In total, the literature is quite poor mainly considering the priority of auditory rehabilitation on the realization of subsequent imaging. However, the current "democratization" of hearing implants and their increasing use in children and adults requires reflection on not only the safety of examinations of healthy volunteers, but also of the implant itself. also on the relevance of the interpretation of imaging especially cerebral. The pilot study done, suggested that the placement of the implant (in this case the Bonebridge) has an influence on the size of the artifact and the possibilities of interpretation. It seems appropriate to continue this protocol of analysis, both on the implants in bone conduction, and also on the cochlear implants to demonstrate the impact of the implant on the MRI images and also the impact of the magnetic field on the implant itself, and possibly publish recommendations for clinical practice.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
BASIC_SCIENCE
Masking
NONE
IRM
Clairval Private Hospital
Marseille, PACA, France
Artefact surface ratio
The primary endpoint will be the percentage of artefact area (SA) induced by the magnetic implant relative to the overall sectional area of the artifactless skull section (SC). The measured artefact surface will therefore be related to the reference surface and the artefact percentage will be calculated by the following formula: Ratio (R) = Area artifact (SA) / Area cut (SC) \* 100
Time frame: 1 day
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Enrollment
21