This study evaluates the difference in postoperative bleeding between two study groups, FDA cleared MONTAGE Settable Resorbable Hemostatic Bone Putty and standard of care (no bone hemostat) during pedicle subtraction osteotomy procedures.
Pedicle Subtraction osteotomy (PSO) is a surgical option for treating several spinal deformities. It has been utilized in alignment disorders of the fused spine, in the lumbar spine to treat large sagittal deformities and in patients with ankylosing spondylitis with thoracolumbar kyphotic deformity. PSO typically results in substantial loss of blood (as much as 2L) with a significant portion of the loss likely occurring at the osteotomy surfaces post-surgically. The control of peri-operative blood loss is considered a critical issue by spine surgeons. A variety of methods have been proposed for the reduction of blood loss during or immediately after spine surgery, including preoperative use of erythropoietin, autologous blood, cell salvage, intra-operative controlled hypotension, and the use of anti-fibrinolytic drugs. Bone hemostats have traditionally not been part of the standard of care to promote hemostasis probably because most traditional options (e.g., bone wax) are nonabsorbable and thus might interfere with fusion at the osteotomy site. MONTAGE is a settable (hardening) bioabsorbable polymer and hydroxyapatite/beta tricalcium phosphate based putty, used in the control of bleeding from bone during spine, orthopedic, craniomaxillofacial, thoracic and other surgical procedures, and has been FDA cleared.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
5
Use of Montage bone hemostat on the cut surfaces of bone at the osteotomy site
Upstate Medical University
Syracuse, New York, United States
Hemostasis
The primary objective of this study is to evaluate the difference in postoperative bleeding between two study groups, FDA cleared MONTAGE and standard of care (no bone hemostat), and the extent to which any transfusion is needed.
Time frame: Week 0
Hemostasis
The primary objective of this study is to evaluate the difference in postoperative bleeding between two study groups, FDA cleared MONTAGE and standard of care (no bone hemostat), with blood loss is measured through drop in hematocrit (HCT).
Time frame: Week 0
Hemostasis
The primary objective of this study is to evaluate the difference in postoperative bleeding between two study groups, FDA cleared MONTAGE and standard of care (no bone hemostat) as wound drain output, if utilized.
Time frame: Week 0
PSO Stability
The secondary objective is the stability of the construct, as measured by whether the correction has maintained stability at 1-year and 2-years post surgery. Each incidence of instability will be categorized as belonging to one of the following groups: 1) hardware malplacement, 2) loosening or dislodgement, 3) nonunion or nonfusion with hardware fracture 4) nonunion or nonfusion without hardware fracture and 5) perihardware fracture.
Time frame: 1-year and 2-years post surgery