Incorporating wire threaded custom tunnel attachments with clear aligner therapy is a novel approach developed to address the shortcomings of the currently available orthodontic systems. This hybrid system is anticipated to take advantage of the benefits and overcome many of the limitations of traditional fixed buccal/lingual appliances and clear aligner therapy. The concept utilizes light arch wires to be threaded through computer designed, chairside-fabricated composite tunnel attachments to achieve better control of three-dimensional tooth movements not achievable by clear aligners, such as Invisalign® (Align Technology, Santa Clara, CA) alone. The superelastic feature of the arch wires allows delivery of more continuous forces than aligners alone, potentially permitting shorter duration of recommended aligner wear during orthodontic treatment. A virtual set-up would be used to plan the desired position of the teeth, which in turn will be used to customize the size and position of composite tunnel attachments based on how two round arch wires will pass through tubes within the attachments. The attachments can be placed on either the buccal or lingual surfaces of teeth, depending on clinical preferences and esthetic demands. This is achievable using in-house aligners, which will also allow the fabrication of aligners in the office or at a conventional orthodontic lab at a fraction of the cost of traditional clear aligners.
Specific aims: * Test and formally describe a novel method that utilizes clear aligners paired with computer-designed, chairside-fabricated tunnel attachments to achieve tooth movements that are challenging for clear aligners. * Conduct a randomized clinical trial to compare the ability of a traditional clear aligner system Invisalign® (Align Technology, Santa Clara, CA) and a clear aligner system incorporating wire threaded tunnel attachments in: * achieving predicted outcomes; discrepancies in bucco-lingual and inciso-gingival positions between the virtual plan and end of treatment intraoral scan and will be measured in millimeters and angular discrepancies will be measured in degrees * end of treatment ABO leveling and alignment objective grading scores Materials and Methods: A virtual set-up is completed by the clinician to plan the position, orientation, and dimension will be customized on the teeth to be moved.Generally, they are spherically shaped and their dimensions are approximately 2-3 mm. Vacuum-formed attachment template will be made to take the shape of a tube-holding spheres, in which tubes are embedded. The tubes are standard in size with an outside diameter of 0.032", and an inside diameter of 0.019" and 2 mm length The template will be loaded with composite after inserting the metal tubes are placed in their predetermined location on the tray. Double tubes will be used when torque control is needed. 0.016" buccal or lingual round wires will be placed into the tunnel attachments along the attachments. Aligners will be delivered to patient to be worn for at least 8 hours a day and changed as determined by the Dental Monitoring application.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Enrollment
34
Tunnel attachments planned virtually and light Nickel Titanium wire
Clear Aligner therapy
1) Horizontal movement in millimeters
The virtual setups (predicted results) and actual results scans will be superimposed using a best-fit alignment method using Geomagic Control X (3D Systems, Rock Hill, South Carolina). Initial alignment will be done using 300 surface points, and fine adjustments will be made using additional 1500 points. This process will be repeated as necessary. Once satisfactory superimposition is performed, the x, y, z coordinates (mm) of dental landmarks on the setup and result arches will be exported and analyzed. Linear and angular measurements will be made to determine the accuracy of each system in achieving predicted vertical, in-out and torque treatment outcomes. The percentage of accurate tooth movement will be determined with the following equation: \[(\|predicted-achieved\|/\|predicted\|) 100%\]
Time frame: 3-12 months of orthodontic treatment
2) Vertical movement in mm
The virtual setups (predicted results) and actual results scans will be superimposed using a best-fit alignment method using Geomagic Control X (3D Systems, Rock Hill, South Carolina). Initial alignment will be done using 300 surface points, and fine adjustments will be made using additional 1500 points. This process will be repeated as necessary. Once satisfactory superimposition is performed, the x, y, z coordinates (mm) of dental landmarks on the setup and result arches will be exported and analyzed. Linear and angular measurements will be made to determine the accuracy of each system in achieving predicted vertical, in-out and torque treatment outcomes. The percentage of accurate tooth movement will be determined with the following equation: \[(\|predicted-achieved\|/\|predicted\|) 100%\]
Time frame: 3-12 months of orthodontic treatment
3) angular movement in degrees
The virtual setups (predicted results) and actual results scans will be superimposed using a best-fit alignment method using Geomagic Control X (3D Systems, Rock Hill, South Carolina). Initial alignment will be done using 300 surface points, and fine adjustments will be made using additional 1500 points. This process will be repeated as necessary. Once satisfactory superimposition is performed, the x, y, z coordinates (mm) of dental landmarks on the setup and result arches will be exported and analyzed. Linear and angular measurements will be made to determine the accuracy of each system in achieving predicted vertical, in-out and torque treatment outcomes. The percentage of accurate tooth movement will be determined with the following equation: \[(\|predicted-achieved\|/\|predicted\|) 100%\]
Time frame: 3-12 months of orthodontic treatment
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.