Investigators team propose to evaluate the impact of the use of intraoperative scanning coupled with Stryker navigation, compared to the conventional fluoroscopy technique, on the accuracy of pedicle screws, in instrumented spinal surgery, by a randomised prospective study, in terms of pedicular screw accuracy. We will also evaluate the radiation exposure of the neurosurgical team and the patient in these two techniques.
The use of pedicle screws in spinal surgery has seen a major advance in recent decades, allowing for greater biomechanical stability and higher fusion rates. In order to avoid any malposition that could cause neurological, vascular and visceral injuries and compromise this mechanical stability, imaging-guided surgical techniques have been developed. These are aimed at improving the positioning accuracy of pedicle screws to reduce these risks and improve mechanical stability and intervertebral fusion. Fluoroscopic examinations had long been the mainstay of intraoperative control imaging until the development of computer-assisted techniques. However, despite intraoperative examination, pedicle screw misalignment remains very common and even experienced surgeons can deviate screws in 5 to 20% of cases when using a standard fluoroscopic examination image. Thus, navigation techniques coupled with an intraoperative scanner, involving the acquisition of 2D images of the surgical field, have been developed. These techniques allow the neurosurgeon to navigate the spine and thus allow an improvement in the positioning accuracy of the pedicle screws. The correlate is an improvement of the safety of the procedure (reduction of complications) but also an optimisation of the biomechanical efficiency of the osteosynthesis. With respect to the radiation emitted during navigated spinal surgery coupled with an intraoperative scan, some comparative studies have shown that the radiation rates received by the neurosurgical team and the patient were lower than the radiation rates received in conventional surgery. To date, few studies combining the analysis of the pedicular screw accuracy rate and the radiation rate transmitted to the neurosurgical team and patients have been published. Therefore the team propose to evaluate the impact of the use of intraoperative scanning (BODYTom, Samsung) coupled with Stryker navigation, compared to the conventional fluoroscopy technique, on the accuracy of pedicle screws, in instrumented spinal surgery, by a randomised prospective study, in terms of pedicular screw accuracy. The investigator team will also evaluate the radiation exposure of the neurosurgical team and the patient in these two techniques.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
NONE
Enrollment
110
surgery with pedicle screw placement between L1 and S1
Clairval Private Hospital
Marseille, Paca, France
RECRUITINGpedicle screw positioning
The accuracy of pedicle screw positioning will be evaluated on the early postoperative examination scan (within 48 hours after the intervention) and graded according to the following classification: * correctly positioned: pedicle screws perfectly positioned in the pedicle or with a deflection of less than 4mm. * poorly positioned: pedicle screws with a deflection greater than 4 mm.
Time frame: 48 hours