Falls are frequent and often serious events in the elderly. The consequences of falls are often severe: traumatic (fractures, hematomas, ..) and psychological. Falls are among the top ten causes of death in this population and, for people older than 70, falls are the leading cause of accidental death. The Damart company has developed a fabric containing ceramic fibers. Clothes containing such fibers have been found to improve balance. This study aims to measure the effect of a t-shirt with a ceramic membrane ("ceramic" t-shirt) on the balance and walking compared to the effect of a "placebo" t-shirt (same weight, appearance and texture). The hypothesis is that wearing the ceramic tee-shirt significantly improves balance and walking, suggesting that it can also reduce falls - the main consequence of the balance and walking disorder.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
QUADRUPLE
Enrollment
60
Short sleeve t-shirt : TRICOT JERSEY VANISE DOUBLE FACE " THERMOLACTYL EVOLUTION " with ceramic fibers. A Tinetti test will be performed while wearing the T-shirt, as well as an evaluation of the equilibration on posturography platform under static conditions and an assessment of dynamic equilibrium and locomotion in motion analysis.
Short sleeve t-shirt : TRICOT JERSEY SIMPLE The comparator T-shirt has the same weight, the same appearance, and will be used by patients in the same way and under the same conditions as the T-shirt with ceramic fibers.
Hôpital gériatrique les Bateliers
Lille, France
Variation of the Tinetti score between the two group
Variation of the Tinetti score between the group T-shirt placebo (Δ Tinetti T-shirt placebo vs Tinetti clothing patients) and the ceramic tee-shirt group (Δ Tinetti ceramic t-shirt vs Tinetti clothing patients). Scoring of the Tinetti Assessment Tool is done on a three point ordinal scale with a range of 0 to 2. A score of 0 represents the most impairment, while a score of 2 represents independence. The individual scores are then combined to form three measures; an overall gait assessment score, and overall balance assessment score, ad a combined gait and balance score.
Time frame: Baseline
variation of the posturography technique
Parameters of the static equilibrium produced by the posturography technique: the length of the balancing path (mm)
Time frame: Baseline
variation of motion analysis (the optoelectronic system (VICON®)
Parameters of the dynamic equilibrium and locomotion produced by the technique of motion analysis. Analysis of gait parameters: speed (seconde) and length (meters). these parameters will be combined to report the dynamic equilibrium and locomotion
Time frame: Baseline
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.