Self-monitoring of blood glucose using capillary glucose testing has a number of shortcomings compared to continuous glucose monitoring (CGM). We aimed to compare these two methods and used blood glucose measurements in venous blood as a reference. Despite considerable inter-individual variability of postprandial glycemic responses, CGM evaluated postprandial glycemic excursions which had comparable results compared to standard blood glucose measurements under real-life conditions.
Self-monitoring of blood glucose using capillary glucose testing (C) has a number of shortcomings compared to continuous glucose monitoring (CGM). We aimed to compare these two methods and used blood glucose measurements in venous blood (IV) as a reference. Postprandial blood glucose levels were measured after 50 g oral glucose load and after the consumption of a portion of different foods containing 50 g of carbohydrates. We also evaluated the associations between postprandial glucose responses and the clinical characteristics of the participants at the beginning of the study. Incremental area under the curve (AUCi) of postprandial blood glucose was calculated for 1 h (AUCi 0-60) and 2 h (AUCi 0-120). Despite considerable inter-individual variability of postprandial glycemic responses, CGM evaluated postprandial glycemic excursions which had comparable results compared to standard blood glucose measurements under real-life conditions.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
12
One day prior to the study beginning, participants were equipped with a CGM system (FreeStyle Libre®, Abbott Diabetes Care, Alameda, CA, USA). This CGM system provides glucose recordings every 15 min over a period of 14 days. The glucose data were downloaded manually by a scan with a handheld device. On the second day of the study, participants consumed portions of these three test products containing 50 g of available carbohydrate on 3 separate days without a washout period. The products were tested in random order at the same time of the morning after a 10 h overnight fast. Venous blood samples were collected at 0, 15, 30, 45, 60, 75, 90, 105 and 120 min postprandial by inserting an intravenous cannula into a forearm vein. Capillary blood samples were obtained through finger pricking. Blood glucose levels in these samples were measured with a high quality SMBG system (ContourXT/Contour next, Ascensia Diabetes Care, Leverkusen, Deutschland, Germany).
West-German Center of Diabetes and Health
Düsseldorf, Germany
Postprandial glucose response
postprandial glycemic changes after consuming different carbohydrate containing foods
Time frame: 1 and 2 hours after food consumption
incremental AUC (AUCi) of postprandial glucose excursions
after consuming different carbohydrate containing foods
Time frame: 1 and 2 hours after food consumption