This study is a prospective, observational, cohort study aiming to compare point-of-care high-sensitive troponin I testing from different sample types with central laboratory (CL) HS cTnI plasma samples. A registry of all included patients and their troponin results (POC, CL and HS cTnT) will be made to compare these testing methods.
Point-of-care (POC) troponin testing, defined as laboratory testing near a patient location with rapid availability of results, has attracted much interest in the emergency department setting (ED) and seems feasible. These devices might enable earlier decisions, reduce stay at the ED and improve patient flow. While an elevated troponin in patients with suspected acute coronary syndrome (ACS) confirms diagnosis and initiates adequate treatment, ruling out ACS aids in proper patient dismissal. A next step could be ruling out myocardial infarction by the general practitioner (GP) or fast responder using an on-site POC troponin test. However, drawing venous blood might not be easily available to every GP, especially not during peak hours. The Minicare cTnI is a bedside system which requires capillary blood, venous whole blood or plasma. The results of the troponin will be given within 10 minutes. It is a very sensitive troponin test, the most clinically sensitive available POC for c-Troponin. Currently Minicare prepares for a high sensitive troponin analysis targeting a reliable result within an hour after onset of chest pain. The objective of this study is to determine if high sensitive troponin testing by Minicare (POC HS cTnI) has the same analytical performance as standard high sensitivity troponin I testing in our central hospital laboratory ( CL HS cTnI ARCHITECT immunoassay analyzer, Abbott).
Study Type
OBSERVATIONAL
Enrollment
131
Point-of-care (POC) high sensitive troponin I (HS cTnI) analysis in whole blood, plasma and capillary whole blood with the Minicare® device.
Viecuri MC
Venlo, Limburg, Netherlands
Method and sample comparison
The primary objective is to compare the analytical performance (method and sample comparison) of Minicare® high sensitive troponin I testing (POC, different sample types) and conventional venipuncture troponin I test in our central hospital laboratory (CL) with the Abbott Architect. This comparison will comprise: * Minicare® POC (different sample types) vs conventional HS cTnI CL test (Method comparison) * Minicare® capillary vs. Minicare® venipuncture and vs. Minicare® plasma (Sample comparison) The analyses linked to the primary objectives are: * The agreement between POC (three sample types) and CL testing by using the Bland-Altman method. * The agreement between different POC sample types by using the Bland-Altman method. The primary objective will be achieved by taking capillary and (an extra) venous blood samples (one per timepoint) from every patient presenting at the cardiac ED with chest pain suspected for ACS.
Time frame: 30 days
Major adverse cardiac event (MACE)
MACE is is defined as a composite of cardiac death and myocardial infarction.
Time frame: 30 days
Final patients diagnoses.
To compare final patients diagnosis (ACS vs. no ACS) and treatment based on POC venous troponin testing versus CL plasma troponin I testing versus HS cTnT plasma testing (regular patient care).
Time frame: 30 days
Overview baseline characteristics.
To create an overview of baseline characteristics of the population.
Time frame: 30 days
Linear regression and Pearson's correlation.
* The relationship between POC (three sample types) and CL by linear regression and Pearson's correlation. * The relationship between POC sample types by linear regression and Pearson's correlation.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 30 days
Fals-positive and fals-negatives.
To compare the proportion of false positive and false negative results between the different POC samples and if there is a significant difference.
Time frame: 30 days
Safety analysis of POC troponin.
To create an overview of the sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of POC and standard laboratory troponin I testing.
Time frame: 30 days