NIRS technology is therefore a technique that exploits the different absorption properties of oxygenated and deoxygenated hemoglobin to evaluate the degree of tissue oxygenation. This hemodynamic response is measured in a completely non-invasive and silent manner, by the simple emission of light passing through different layers of biological tissue. In the literature, some studies concerning the use of the NIRS method for the study of urodynamics exist. They seem to show a correlation between the data of the urodynamic assessment and the data obtained with the NIRS method. Certain trends seem to be repeated with, for example, an increase in oxyhemoglobin at the beginning of the filling phase and the beginning of the urination phase. The aim of the study is to analyze the NIRS signal and find correlation with urodynamic data.
The main objective is to detect a urodynamic variation of the detrusor muscle during a contraction.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DEVICE_FEASIBILITY
Masking
NONE
Enrollment
40
Patient has a NIRS module during their urodynamic exam.
Rangueil Hospital
Toulouse, France
optical measurement of hemoglobin concentrations
concentrations of oxygenated O2Hb, provided from a NIRS module
Time frame: 9 months
detrusor pressure measurement (Pdet)
Pdet during filling and emptying of the urodynamic exam
Time frame: 1 hour
optical measurement of hemoglobin concentrations
concentrations of deoxygenated HHb, provided from NIRS module
Time frame: 9 months
optical measurement of hemoglobin concentrations
concentrations of total tHB provided from NIRS module
Time frame: 9 months
optical measurement of hemoglobin concentrations
concentrations of oxygenated O2Hb, provided from NIRS module
Time frame: 9 months
detrusor pressure measurement (Pdet)
Pdet during filling and emptying of the urodynamic exam
Time frame: 1 hour
optical measurement of hemoglobin concentrations
concentrations of deoxygenated HHb, provided from NIRS module
Time frame: 1 hour
clinical annotations of the doctor performed on the report of the urodynamic exam
Normality of detrusor function (YES/NO), hyperactive detrusor function (YES/NO) , hypoactive detrusor function (YES/NO). Criteria assessed by the investigator by a response (yes/No)
Time frame: 1 hour
optical measurement of hemoglobin concentrations
concentrations of total tHB provided from NIRS module
Time frame: 9 months