Rationale: Prostate cancer (PCa) is the second cause of cancer-related deaths for men. The standard surgical treatment for localised prostate cancer is radical prostatectomy. Possible side effects of this treatment are incontinence and erectile dysfunction and this is related to the whole-gland resection. A focal treatment with fewer side effects is desired for patients with only a small focus of PCa. For this purpose, focal laser ablation is feasible. Current focal laser ablation techniques use a single fibre setup with the need for fibre replacement revisualisation of the tumour side accordingly. This leads to a long treatment duration. The Echolaser® system is a laser ablation system with four simultaneously operating laser sources. This provides a potential larger treatment area, without the need for fibre replacement. This makes the system advantageous for focal laser ablation of prostate cancer, especially since it can be applied under local anaesthesia. This pilot study aims to evaluate histological ablative efficacy on radical prostatectomy specimens following TPLA, feasibility and safety using a (multi)fibre setup in men with localized prostate cancer. The investigators hypothesize that TPLA will show adequate histological ablative efficacy and will be feasible and safe.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
12
Transperineal laser ablation
Academic Medical Center
Amsterdam, North Holland, Netherlands
Ablative efficacy of transperineal laser ablation determined by size of the ablation zone in histopathology, which is measured by absence of vital prostatic cells, compared to the size measured on imaging (CEUS/MRI) during and after treatment
Histological ablative efficacy is assessed on histopathological analysis of the prostatic tissue after radical prostatectomy by means of the absence of vital cells in the treated prostate zone
Time frame: 30 days following TPLA treatment
Safety is assessed by device and procedural adverse events using the CTCAEv5.0 until radical prostatectomy and feasibility is determined by procedural success of the TPLA treatment.
Safety is assessed by device and procedural adverse events using the CTCAE v5.0 until radical prostatectomy. TPLA is definitely safe when ≤10% of patients experience major adverse events, defined as grade 3 or higher. Technical feasibility is determined by procedural success of the TPLA treatment. TPLA is definitely feasible when ≥90% of procedures is performed successfully without any problems regarding needle placement, fibre introduction or device malfunctioning.
Time frame: 30 days following TPLA treatment
Size of ablation zone
Determination of the size of the ablated area
Time frame: 30 days following TPLA treatment
Observation of tissue changes seen on imaging during and after treatment compared to histopathology
Ablation zone volumes are measured using CEUS and mpMRI and these are used to determine ablation zone compared to histopathological changes. Visual changes are identified and described.
Time frame: 30 days following TPLA treatment
Functional outcomes measured using PROMs (VAS, IPSS, IIEF-15, EPIC)
Determination of short-term functional outcomes following TPLA treatment
Time frame: 30 days following TPLA treatment