Introduction: The concept of immediate implant placement has become popular due to reduced trauma and reduced overall treatment time. Removal of molar teeth provides a challenging and intriguing dilemma due to multiple root morphology. In cases of extraction and immediate placement of implants in the molar region, removal of the inter-radicular septum should be avoided to attain initial implant stability at the time of placement, and prevent slipping of the implant into the extraction socket. Following this technique prevents the slippage of the implant and allows the implant to be guided into the inter-radicular septum. Objectives: To assess the accuracy of implant placement using the remaining roots of multi-radicular mandibular molars, evaluate bone density around implants and implant stability in fresh extracted site. Materials and Methods: A prospective study was done on 10 patients with badly destructed mandibular molars. The technique of implant insertion consisted of a progressive preparation of the implant site using the anatomy of the root of the multi-radicular mandibular molars to be extracted as a reference and as an aid to engage the inter-radicular septum.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
10
The technique of implant insertion consisted of a progressive preparation of the implant site using the anatomy of the root of the multi-radicular mandibular molars to be extracted as a reference and as an aid to engage the inter-radicular septum
Faculty of Dentistry Alexandria university
Alexandria, Egypt
implant stability quotient
implant stability quotient will be assessed using Osstell device.
Time frame: 3 months
Implant position accuracy using cone beam computed tomography
Immediate postoperative and a preoperative conebeam CT will be done. The preoperative and postoperative scans will then be over¬lapped using a dedicated algorithm, which will allow the comparison of the virtually planned and the actual implant positions. Three deviation parameters between each planned and placed implant will be measured. All measurements will be performed using Mimics Innovation Suite 19 ™ software (Materialise Mimics software 3D Medical Imaging, Belgium). For analyzing the accuracy, the planned position of the implant will be compared with the actual position of the implant after insertion. Several measuring points will be measured: * Horizontal deviation at coronal side of the implant. * Horizontal deviation at apex of the implant. * Angular deviation.
Time frame: immediately
Bone density around implant
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.