To study the effect of myocardial microcirculation disturbance on coronary flow reserve fraction, compare the evaluation value of IMR, FFR and QCA on myocardial ischemia, and discuss the correlation among them.
In this study, 60 patients with critical lesions indicated by coronary angiography will be admitted. The investigators collected the basic clinical data (gender, age, body mass index, smoking history, hypertension, diabetes, hyperlipidemia), laboratory data (creatinine, cholesterol, triglycerides) and measured their FFR and IMR.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
60
FFR measurement: Pressure guid wire(radianalyzer Xpress 12711) is produced in Switzerland. After the pressure of the aorta and the pressure guide wire is balanced, Send the pressure guide wire to the distal part of the lesion(more than 20 mm away from the lesion) . Adenosine is injected into the vein,then,record the FFR index 3 times and take the average value as the final measurement index.
The people's hospital of LiaoNing Province
Shenyang, Liaoning, China
IMR
Resistance index of microcirculation
Time frame: one hour
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.