Researchers are assessing the ease of use and accuracy of the HeraBEAT™ device, a new device used with a smartphone to monitor fetal heart rate during pregnancy.
The HeraBEAT™ is a wireless Smart Fetal Ultrasound Doppler measuring device designed to be self-administered by the expectant mother throughout the different stages of pregnancy. The HeraBEAT™ device safety and performance claims allow continuous and accurate measurement of fetal heart rate (FHR) and maternal heart rate (MHR) throughout the pregnancy starting at 12 weeks gestation. Technologically, HeraBEAT™ is similar to other FHR devices currently on the market in terms of device usage but differ by design in its interface. The HeraBEAT™ device uses a smartphone-based interface, with real time instructions for expectant mothers for determining both MHR and FHR. This study will recruit low risk expectant mothers from the Obstetrics and Gynecology Department at Mayo Clinic Rochester. This is a mixed method; single center randomized controlled trial comparing HeraBEAT™ to a standard home fetal Doppler monitor, in the outpatient setting at a single academic institution, in the mid-west United States. The overall study will be guided by an assessment of device functionality and user acceptability, as well as an evaluation of the impact of the device on expectant mother's perception of fetal well-being, as measured by standardized surveys.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
59
A wireless Smart Fetal Ultrasound Doppler measuring device designed to be self-administered by the expectant mother throughout the different stages of pregnancy
A hand-held ultrasound transducer that uses the Doppler Effect to provide an audible simulation of the heart beat and displays the number of beats per minute.
Mayo Clinic
Rochester, Minnesota, United States
Device Ease of Use
Measured using the self-reported System Usability Scale (SUS) on 10 items, each on a scale from 1 to 5 (1 = strongly disagree and 5= strongly agree). A composite score is calculated with a range of 0-100 where higher values indicated a high usability of device, whereas lower scores indicate less usability of the device.
Time frame: 8 weeks
Accurate Fetal Heart Rate Detection Where Values Are Between 110 and 160 Bpm
Number of patients to detect a fetal heart rate accurately using the device. An inaccurate assessment is considered any value less than 110 or greater than 160 bpm. A patient with at least one inaccurate value is counted as an event of interest. Patients without an inaccurate event will be counted as a success.
Time frame: 8 weeks