In the context of fetal heart monitoring (prenatal and during childbirth), the SurFAO project offers an alternative to current clinical routines. The challenge is to extract, from non-invasive sensors on the maternal abdomen, a fetal electrocardiogram (ECGf) of great quality allowing a clinical diagnosis (follow-up of the FHR (Fetal Heart Rate)) and extraction of ECG waveforms). The approach proposes a technological breakthrough shared by a consortium of researchers and clinicians. The originality is driven by innovative methodological choices: the use of a multimodal system (ECG coupling with PCG (phonocardiography)) for the signal acquisition in order to increase the robustness of information extraction, by taking into account clinical uses and the need to support the monitoring process, and by setting up a multimodal database. The objective is to feed a database that will be used in the future to develop ECGf extraction methods.
To monitor the well-being of a fetus or for clinical diagnosis, the challenge is to extract a high-quality fetal electrocardiogram (fECG) signal from non-invasive sensors on the maternal abdomen. As early as the 20th week of amenorrhea, heart rhythm disorders (tachycardia, bradycardia) can be detected in the fetus, most often by fortuitous circumstance, during routine obstetrical ultrasound examinations. It is then necessary to analyze these rhythmic anomalies, understand their origin and, if necessary, initiate pharmacotherapy. The effectiveness of the treatments is then monitored by ultrasound in the high-risk pregnancy department. The analysis of a fetal electrocardiogram (fECG) provides information that allows to determine the nature of the rhythm disorder, its origin and therefore its potential severity. The innovative methodological approach considered for the extraction of non-invasive ECGf is to combine 2 complementary modalities of the same cardiac phenomenon. This is achieved by combining the use of ECG sensors with sound sensors giving access to phonocardiographic signals (PCG).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
20
The ECG - PCG signals are acquired over a 20-minute monitoring phase with passive non invasive sensors (abdominal and thoracic). The volunteer's abdomen is photographed when the electrodes and sensors are installed. An ultrasonography is also performed for 10 minutes. The session is filmed for 5 volunteers accepting the video. Any distinctive elements will be removed from photos and videos to prevent the identification of participants.
University Hospital Grenoble Alpes
Grenoble, France
RECRUITINGECG / PCG Signals database
Synchronized signals from ECG electrodes and PCG sensors. Signals will be processed to extract fetal ECG and specific waveforms characteristics of fECG (in parts of R waves, P waves, QT intervals, ST intervals).
Time frame: 20 minutes
Ultrasound signals database
The fetal heart activity is analyzed using mechanograms and Doppler during ultrasound (gold standard).
Time frame: 10 minutes
Subject acceptability : Score
The subject acceptability score will be composed by the addition of 7 scales. These scales have been specifically created for the SurFAO system. The score can go from 0 (worst) to 70 (best). Each scale can give from 0 to 10 points to the final score.
Time frame: 10 minutes
Subject Acceptability : Descriptive analysis
Open questions will be asked to the subjects in a questionnaire. A descriptive analysis will be done with the answers.
Time frame: 10 minutes
Use Error evaluation : System Usability Scale (SUS)
The System Usability Scale (SUS) is a validated tool for assessing the subjective usability of a system, in this case, the SurFAO System. It contains 10 questions that are rated on a scale from 1 to 5. "The participant's scores for each question are converted to a new number, added together and then multiplied by 2.5 to convert the original scores of 0-40 to 0-100." Jeff Sauro established the average score of SUS is 68. The score can go from 0 (worst) to 100 (best).
Time frame: 10 minutes
Use Error evaluation : Descriptive analysis
Difficulties in using the system will be recorded in the case report form and identified using photographs and video. A descriptive analysis will be done.
Time frame: 60 minutes
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.