Although some important progresses were made in the field of the meridian research, no breakthroughs have been achieved. Besides,there are some problems in meridian researches. The majority of the existing studies involve lots of subjective assessments for meridian phenomena. In addition, few studies have investigated the site specificity between two specific meridians.Therefore, this study is designed to detect the microcirculatory characteristics of meridian phenomena by using an objective assessment tool and investigate the site specificity for the meridian-visceral association and surface-surface association between two specific meridians.
The Lung and Heart meridians are chosen as two specific studied meridians. 120 participants will be enrolled and divided into the healthy control group, chronic obstructive pulmonary disease (COPD) group and healthy intervention group. Laser doppler flowmetry (LDF) will be used to assess the microcirculatory characteristics of meridian phenomena for the Heart and Lung meridians. The site specificity for the meridian-visceral association will be investigated by comparing the microcirculatory difference between the Heart and Lung meridians in the healthy control group and COPD group. Besides, participants in the healthy intervention group will receive two sessions of moxibustion in the Heart meridian and Lung meridian respectively to explore the site specificity for the surface-surface association.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
120
Two sessions of moxibustion will be performed in the Heart meridian and Lung meridian successively. Intervention in the Heart meridian: moxibustion will be performed above Shaohai (HT3) for 15 minutes. During moxibustion, the probes of laser doppler flowmetry will detect the microcirculatory characteristics of three measuring sites, which include the midpoint of the Heart meridian along the left forearm, Chize (LU5) of the Lung meridian, and the midpoint of the Lung meridian along the left forearm. Intervention in the Lung meridian: moxibustion will be performed above Chize (LU5) for 15 minutes. During moxibustion, the probes of laser doppler flowmetry will detect the microcirculatory characteristics of three measuring sites, which include the midpoint of the Lung meridian along the left forearm, Shaohai (HT3) of the Heart meridian, and the midpoint of the Heart meridian along the left forearm.
Laser doppler flowmetry will be used to detect the microcirculatory characteristics of meridian phenomena for the Heart meridian and Lung meridians.
the Third affiliated hospital of Zhejiang Chinese Medical university
Hangzhou, Zhejiang, China
Change from baseline blood flow curve
Laser doppler flowmetry is used to assess blood flow curve of relevant sites along the Heart and Lung meridians
Time frame: 5-minute baseline, 15 minutes during moxibustion and 5 minutes after stopping moxibustion
Change from baseline blood perfusion units
Laser doppler flowmetry is used to assess blood perfusion units of relevant sites along the Heart and Lung meridians
Time frame: 5-minute baseline, 15 minutes during moxibustion and 5 minutes after stopping moxibustion
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.