Myofascial pain syndrome (MPS) is a musculoskeletal disorder which is characterized by pain, muscle spasms and muscle tenderness, as well as a limited range of motion, weakness, and rarely, autonomous dysfunction.
The occurrences of morbidity of the neck after cancer therapy were considerable and consisted of neck pain, loss of sensation, and decreased range of motion. Extracorporeal shock wave therapy (ESWT) is one of the treatment options used for patients with myofascial pain syndrome through elimination of ischemia and modulation of vasoneuroactive substance (two major causes of trigger pathophysiology) and mechanical transduction as a cellular response to external stimulation. the aim of this study was to investigate efficacy of extracorporeal shock wave therapy (ESWT) on cervical myofascial pain following neck dissection surgery.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
46
Extracorporeal Shock Wave Therapy (ESWT) has been introduced efficiently for more than twenty years as a treatment modality in orthopedic and musculoskeletal disorders. ESWT has mechanical and cellular impacts on tissues regeneration and pain management through cavitation bubbles, acoustic micro streaming, and hyper-vascularity that can directly affect tissue calcifications, and modulate cell activity.
participants received 1% topical diclofenac gel on the tender points 3 times /day for 4 weeks.
Faculty of Physical Therapy, Cairo University
Cairo, Egypt
Visual analogue scale
VAS was utilized for assessing and quantifying pain exhibited by the patients through a 0-10 cm scale. Each subject was informed to mark the line according to the pain intensity experienced at that particular time where '0' means no pain and '10' means worst conceivable pain.
Time frame: before treatment
Visual analogue scale
VAS was utilized for assessing and quantifying pain exhibited by the patients through a 0-10 cm scale. Each subject was informed to mark the line according to the pain intensity experienced at that particular time where '0' means no pain and '10' means worst conceivable pain.
Time frame: 2 weeks of treatment
Visual analogue scale
VAS was utilized for assessing and quantifying pain exhibited by the patients through a 0-10 cm scale. Each subject was informed to mark the line according to the pain intensity experienced at that particular time where '0' means no pain and '10' means worst conceivable pain.
Time frame: after 4 weeks of treatment
Cervical range of motion assessment
Cervical range of motion device (CROM; Performance Attainment Associates) was used for assessment of neck lateral flexion and rotation of both sides. The CROM instrument contains a plastic frame put on the head above the nose and ears, attached at the head back by a Velcro strap to allow precise measure, re-measure and rotational motion in an upright place to avoid individual errors. Two independent inclinometers are connected to the frame and point the head position in relation to the gravity line. Another inclinometer indicates the head position in rotation in relation to a reference position.
Time frame: before treatment
Cervical range of motion assessment
Cervical range of motion device (CROM; Performance Attainment Associates) was used for assessment of neck lateral flexion and rotation of both sides. The CROM instrument contains a plastic frame put on the head above the nose and ears, attached at the head back by a Velcro strap to allow precise measure, re-measure and rotational motion in an upright place to avoid individual errors. Two independent inclinometers are connected to the frame and point the head position in relation to the gravity line. Another inclinometer indicates the head position in rotation in relation to a reference position.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 2 weeks of treatment
Cervical range of motion assessment
Cervical range of motion device (CROM; Performance Attainment Associates) was used for assessment of neck lateral flexion and rotation of both sides. The CROM instrument contains a plastic frame put on the head above the nose and ears, attached at the head back by a Velcro strap to allow precise measure, re-measure and rotational motion in an upright place to avoid individual errors. Two independent inclinometers are connected to the frame and point the head position in relation to the gravity line. Another inclinometer indicates the head position in rotation in relation to a reference position.