This is a one-arm, open label, prospective, single center study to evaluate clinical standardization with Theraclion's Sonovein 2 HIFU device. The original Sonovein device was tested in a clinical trial in 50 subjects and received CE Mark. That device has been updated yielding the current version of Sonovein 2. Based on the technical similarities between both devices in term of design, performance and principle of operation, the clinical data for Sonovein is sufficient to assure conformity of the Sonovein 2 with the respected essential requirements. At the same time, the compagny wishes to pursue the standardisation of the clinical practice with the second generation device and is, therefore, conducting this limited trial in 20 evaluable cases (from the planned 22 patients to be included). A "case" is defined as procedure conducted on a distinct vein.
The Sonovein 2 system provides high intensity focused ultrasound (HIFU) abaltion of soft tissue. The energy is delievered via an extra-corporeal treatment probe, which includes an imaging system. The high energy ultrasound waves propagate through the skin and are focused on a portion of the target tissue, generating intense heat and causing local cell apoptosis and progressive tissue volume reduction over the following months in the tissue within the focal area. The process is then repeated in a stepwize fashion to destroy the targeted tissues. The Sonovein 2 system is comprised of several components, including the console, treatment arm containing the visualization and treatment unit (VTU), a computer with touchscreen user interface. In addition, the Sonovein 2 system is intended to be used in conjunction with a disposable cooling and coupling system known as ePack.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
22
Patient are treated with the HIFU device and the pysician is doing a compressive bandage
Karl Landsteiner Institut für funktionelle Phlebochirurgie
Melk, Austria
Reduction of venous reflux
As measured by ultrasound
Time frame: 3 months
Emergent Adverse Events
Measure of AEs and SAEs recorded in AE form at each visit
Time frame: 3 months
Measurement of the need to use tumescence anesthesia during the procedure
Evaluated dichotomously present/absent
Time frame: 3 months
Measurement of the need to use adjunctive procedure for treating the reflux
Evaluated dichotomously present/absent
Time frame: 3 months