This study was carried out to determine the effect of the use of communication material on the anxiety and comfort of the patient in communication with patients receiving mechanical ventilators.As a result, the use of communication material reduces anxiety and increases patient satisfaction and comfort level. In communicating with intubated patients receiving mechanical ventilator therapy, the use of illustrated communication material is recommended.
The use ofcommunication material in communication with patients receiving mechanical ventilator support increases patient satisfaction and reduces communication difficulties. However, there was no randomized controlled clinical study showing the effect of the use of these materials on patient care outcomes such as anxiety and comfort level.Patients were randomly assigned to the control groups using illustrated communication material and intervention and routine communication methods. The research was carried out in three stages: preoperative, intensive care and one day after surgery. The primary outcomes of the study were pain, anxiety and comfort levels of the patients. Secondary outcomes were the patients' satisfaction with hemodynamic parameters and communication method.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
60
Illustrated communication material was introduced to the patients in the intervention group. In the process (intensive care) that patients received mechanical ventilation support after the operation, agitation and sedation levels were monitored by the intensive care nurse who was to communicate with the patient using the Richmond Agitation Sedation Scale (RASS). According to this scale, having minimum -2 and maximum +2 points was accepted as the starting criteria for communication (Sessler et al., 2002). Communication was established with the illustrated communication material.
change of anxiety over time
it was measured by using the Faces Anxiety Scale
Time frame: The anxiety scores were recorded by the intensive care nurse in three consecutive measurements starting with the first communication (0th minute) and at 30th and 60th minutes
comfort level
Postoperative comfort levels of the patients were determined by the Early Postoperative Comfort Scale.The highest total score that can be obtained from the scale is 144, and the lowest total score is 24. High scores show that comfort is good, and low scores show that comfort is depraved
Time frame: 1 day after surgery
hemodynamic data
hemodynamic data are systolic and diastolic blood pressure, heart rate, respiration rate, and peripheral oxygen
Time frame: Hemodynamic data were recorded through the patient monitor by intensive care nurses in three consecutive measurements starting with the first communication (0th minute) and at 30th and 60th minutes
communication satisfaction and adequacy of communication techniqu, change of pain over time
It is stated that numerical scales have been adopted more in clinical practice because they are useful in facilitating the definition of pain intensity, facilitating scoring and recording, and evaluating ceiling and floor effects. "The Numerical Evaluation Scale" was used to determine the pain levels of patients and to evaluate their satisfaction with the communication method used and the adequacy of the method
Time frame: Pain data were recorded as 30th and 60th minutes, starting from the first communication (0th minute) in mechanical ventilation. Satisfaction and adequacy of communication were evaluated an average of 24 hours after surgery
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.