Cardiac output (CO) assessment is one of the cornerstone of hemodynamic evaluation in ICU patients. CO is usually measured using invasive methods or non-invasive methods. Thermodilution is considered as the gold standard for CO assessment. Cardiac Doppler as well demonstrated to be accurate but needs manipulations and good knowledge and skills. The investigators developed a new technique using injection of agitated saline solution to evaluate CO without any manual measurement and then observer independent.
The investigators decided to conduct a prospective observational study to compare contrast assessment of CO and cardiac Doppler technique. Patients hospitalized in ICU will be included if they need a trans esophageal echocardiographic evaluation and a research of intra cardiac shunt (using a saline contrast test). Patients with Swan Ganz catheter will be included as well. Cardiac output will be measured using cardiac Doppler. Simultaneously, 4.5 ml of saline with 0.5 ml of air will be agitated to have a contrast solution. This solution will be injected as usual and echocardiographic imaging will be recorded. These imaging will be analyzed off-line and CO will be calculated with an algorithm previously developed and compared with the reference method. In case of swan ganz catheter, the cardiac output will be also measured using the thermodilution technique.
Study Type
OBSERVATIONAL
Enrollment
65
Patients hospitalized in ICU will be included if they need a trans esophageal echocardiographic evaluation and a research of intra cardiac shunt (using a saline contrast test). Patients with Swan Ganz catheter will be included as well. Cardiac output will be measured using cardiac Doppler. Simultaneously, 4.5 ml of saline with 0.5 ml of air will be agitated to have a contrast solution. This solution will be injected as usual and echocardiographic imaging will be recorded. These imaging will be analyzed off-line and CO will be calculated with an algorithm previously developed and compared with the reference method. In case of swan ganz catheter, the cardiac output will be also measured using the thermodilution technique.
Patients hospitalized in ICU will be included if they need a trans esophageal echocardiographic evaluation and a research of intra cardiac shunt (using a saline contrast test). Patients with Swan Ganz catheter will be included as well. Cardiac output will be measured using cardiac Doppler. Simultaneously, 4.5 ml of saline with 0.5 ml of air will be agitated to have a contrast solution. This solution will be injected as usual and echocardiographic imaging will be recorded. These imaging will be analyzed off-line and CO will be calculated with an algorithm previously developed and compared with the reference method. In case of swan ganz catheter, the cardiac output will be also measured using the thermodilution technique.
CHU Amiens
Amiens, France
RECRUITINGvariation of cardiac output assessment (CO)
correlation will be done between contrast and the reference method cardiac Doppler method.
Time frame: day 0
variation of cardiac output assessment (CO) in patients with a swan gaz catheter
comparison will be performed between the contrast CO and the thermodilution CO in the group of patients with a swan ganz catheter
Time frame: day 0