Alignment of the prosthesis with the stump is performed through the socket. Good socket stump fit provides near-normal posture and weight-transfer pattern. It also ensures that the walk is painless and low-energy. Recently, studies have been carried out to use 3D printers in socket production. 3D method is accepted as an effective and reliable method in prosthetic socket production. The purpose of this study is to compare the pressures distrubution in the sockets produced by conventional and 3D scanners and printers in the transtibial amputee.
Study Type
OBSERVATIONAL
Enrollment
30
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
Marmara University
Istanbul, Turkey (Türkiye)
Measurement of load distrubution on stump in conventional manufactured socket
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
Time frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Measurement of load distrubution on stump in 3D manufactured socket
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
Time frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Measurement of load distrubution on stump in conventional manufactured socket
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Time frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Measurement of load distrubution on stump in 3D-manufactured socket
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Time frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
Time frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
Time frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
Time frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
Time frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.