Lower limb amputation is a factor that changes the individual's weight transfer, gait pattern, and trunk balance. This change plantar pressure distribution of both side and cause a series of problems to be exposed over time according to level of amputation. The aim of this study is to reveal the relationship between amputation level-postural balance and amputation level-plantar pressure distribution.
Study Type
OBSERVATIONAL
Enrollment
85
Standing bipedal with open eyes on force platform
Standing bipedal with closed eyes on force platform
Standing bipedal with open eyes and with platform under heel of prosthetic foot on force platform
Marmara University
Istanbul, Turkey (Türkiye)
Measurement of plantar pressure distrubution
Plantar pressure distrubution (mmHg/N) will be measured by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal with open eyes
Time frame: Change from baseline plantar pressure distrubution at second 10, second 20 and second 30.
Measurement of plantar pressure distrubution
Plantar pressure distrubution (mmHg/N) will be measured by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal with platform under heel
Time frame: Change from baseline plantar pressure distrubution at second 10, second 20 and second 30.
Determination of center of pressure
Determination of center of pressure (cm) will be provided by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal with open eyes
Time frame: Change from baseline center of pressure at second 10, second 20 and second 30.
Determination of center of pressure
Determination of center of pressure (cm) will be provided by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal with platform under heel.
Time frame: Change from baseline center of pressure at second 10, second 20 and second 30.
Measurement of plantar pressure distrubution
Plantar pressure distrubution (mmHg/N) will be measured by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal with closed eyes
Time frame: Change from baseline plantar pressure distrubution at second 10, second 20 and second 30.
Measurement of plantar pressure distrubution
Plantar pressure distrubution (mmHg/N) will be measured by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal without platform under heel
Time frame: Change from baseline plantar pressure distrubution at second 10, second 20 and second 30.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Standing bipedal with closed eyes and with platform under heel of prosthetic foot on force platform
Determination of center of pressure
Determination of center of pressure (cm) will be provided by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal with closed eyes
Time frame: Change from baseline center of pressure at second 10, second 20 and second 30.
Determination of center of pressure
Determination of center of pressure (cm) will be provided by force platform (F-Scan 6.70 TekScan, Boston, MA) on bipedal without platform under heel.
Time frame: Change from baseline center of pressure at second 10, second 20 and second 30.