Pregnancy is associated with a myriad of physiologic changes, including expansion of blood volume, decrease in oncotic pressure, and increased cardiac output. The obstetric population is associated with intrapartum hemorrhage. Accordingly, it is important to have an accurate method to assess fluid status in intrapartum patients. The use of standard volume assessment tools including arterial lines and central venous catheters is limited given the brevity of obstetric procedures and the morbidity of these techniques on the awake patients, and the costs. Non-invasive methods to assess volume status (carotid dopplers, direct measurement of blood loss, bio-impedance devices) are imperfect. Echocardiography is an attractive tool to measure fluid status in experienced operators such as anesthesiologists. IVC diameter and variation of aortic velocity time integral are two measures that can be obtained via echocardiography and been studied in spontaneously breathing patients. The purpose of this study is to determine whether these measurements can be used in the assessment of volume status in the laboring patient.
Pregnancy is associated with a myriad of physiologic changes, including expansion of blood volume, decrease in oncotic pressure, and increased cardiac output. Comorbidities including maternal hypertension, renal or cardiac disease may further complicate the assessment of volume status and are associated with increased risks related to fluid administration (c). In addition, the majority of obstetric patients receive neuraxial analgesia or anesthesia to facilitate both vaginal and operative delivery. These techniques are associated with hemodynamic changes including maternal hypotension secondary to a decrease in SVR and CO. These changes may in turn be associated with a reduction in placental blood flow affecting fetal outcome, and may also cause maternal nausea, vomiting and dizziness. Further, the obstetric population is high risk for intrapartum hemorrhage. As such, it is critical to have an accurate method to assess fluid status in intrapartum patients. The use of invasive volume assessment tools including arterial lines and central venous catheters is limited given the brevity of obstetric procedures, the morbidity of these invasive techniques for the awake patient, and the associated time and costs (b). Non-invasive methods that assess volume status in the obstetric population include techniques such as direct measurement of blood loss (g), carotid dopplers (c), bio-impedence devices (f); However these methods have been shown to be imperfect and are not widely used. Echocardiography is a non-invasive, widely-available tool that can provide rapid information for experienced operators such as anesthesiologists. Respiratory variations in inferior vena cava diameter (IVCd) and variation in aortic velocity time integral (∆VTI) following passive leg raise have been extensively studied in spontaneously breathing patients. IVCd has been shown to predict fluid responsiveness, however requires a high threshold (\>40-50% collapsibility) to detect a difference. IVCd may also change with diaphragmatic motion, thus results may be confounded if the patient becomes tachypneic (d) or is spontaneously breathing (g). In contrast, aortic velocity time integral (∆VTI) may be a more sensitive indicator of volume status. Lamia et al showed a 12% change in VTI as 77% sensitive and 100% specific for a 15% change in cardiac output following 500 mL volume expansion in ICU patients with shock (both spontaneously breathing and mechanically ventilated, e). While there are some studies of IVC collapsibility in the obstetric population, there are limited data on VTI as a measure of volume status in laboring patients. The purpose of this study is to determine whether the aortic velocity time integral (VTI) is influenced by intravascular fluid administration during cesarean section. Secondary aims include determining whether inferior vena cava diameter (IVCd), blood pressure, and heart rate are influenced by intravascular fluid administration during cesarean section. Additionally, total amount of vasopressor agents administered during the procedure will be recorded.
Study Type
OBSERVATIONAL
Enrollment
50
the intervention is one liter fluid bag of lactated ringers which is routinely used as a fluid coload for spinal anesthesia. All patients will receive the same amount of fluids however this will be paused at various time points in order to perform the echocardiogram.
Ben Taub General Hospital
Houston, Texas, United States
RECRUITINGaortic velocity time integral
the percent change in aortic velocity time integral as measured by transthoracic echo
Time frame: at baseline measure, right after spinal placement (250mL LR), at 500mL LR infusion, and at 1 L LR infusion (approximately 20mins)
inferior vena cava collapsibility
the percent change in diameter of inferior vena cava as measured by transthoracic echo
Time frame: at baseline measure, right after spinal placement (250mL LR), at 500mL LR infusion, and at 1 L LR infusion (approximately 20mins)
change in systolic blood pressure
percent change in systolic blood pressure
Time frame: every 2.5 mins for 20 mins (when 1L LR is administered) once the pt has a spinal placement
change in heart rate
percent change in heart rate
Time frame: every 2.5 mins for 20 mins (when 1L LR is administered) once the pt has a spinal placement