The emergence of minimally invasive glaucoma surgeries (MIGS) has seen a variety of potential innovative surgical alternatives to help better control intraocular pressure (IOP). The OMNI™ Surgical System (Sight Sciences, Menlo Park, CA, USA) is a promising MIGS procedure. It combines two procedures known as trabeculotomy and viscodilation of Schlemm's canal in one hand held device without the need for additional incisions or extra instrumentation. The device recently received FDA approval in the United States for certain indications in ophthalmic surgery. To date, no study has examined the effect of standalone viscodilation and trabeculotomy on glaucoma drop burden and IOP.
The emergence of minimally invasive glaucoma surgeries (MIGS) has seen a variety of potential innovative surgical alternatives to help better control intraocular pressure (IOP).1 The OMNI™ Surgical System (Sight Sciences, Menlo Park, CA, USA) is a promising procedure which targets the conventional outflow pathway.2 This device treats the trabecular meshwork, Schlemm's canal and the distal collector channels, all conventional pathway points of aqueous outflow resistance. Its designed microcatheter allows for cannulation of Schlemm's canal, dilation using the controlled delivery of viscoelastic as well as a trabeculotomy by stripping the trabecular meshwork will retracting the catheter.3 Goniotomy-assisted transluminal trabeculotomy (GATT) has shown promising results in using an ab interno approach to cleave the trabecular meshwork.4 Alternatively, viscodilation alone has also shown an IOP lowering effect. 5 The OMNI Surgical System combines both procedures in one hand held device without the need for additional incisions or extra instrumentation. The device recently received FDA approval in the United States for delivery of small amounts of viscoelastic fluid during ophthalmic surgery and to cut trabecular meshwork tissue during trabeculotomy procedures.6 To date, no study has examined the effect of standalone viscodilation and trabeculotomy on glaucoma drop burden and IOP.
Study Type
OBSERVATIONAL
Enrollment
30
GATT + viscodilation
Prism Eye Institute
Oakville, Ontario, Canada
Lower Intraocular Pressure and medication dependence
Change in IOP less than or equal to baseline with a medication reduction to 1 or less or an IOP change of 20% or less from baseline with medication
Time frame: Postoperative week 1, month 1, month 3, annually
Examine the adverse event profile of the OMNI surgical system in patients with open angle glaucoma.
Absence of the following complications: 1\. ) Starting after POM1: shallow AC w/ iridocorneal touch, any hyphema, corneal edema, wound leak/dehiscience, choroidal effusion, malignant glaucoma, dellen/non-healing epithelial defect, ptosis, diplopia, and/or; 2.) At any point: additional glaucoma surgery, loss of light perception vision, vitreous hemorrhage, ≥2mm hyphema, hypotony maculopathy, macular edema, choroidal effusion/hemorrhage requiring drainage, suprachoroidal hemorrhage, retinal detachment, endophthalmitis
Time frame: 1 month post operatively
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.