This is a randomized controlled trial of isolated patients with diabetes admitted to Nordsjællands Hospital with or without COVID-19-pneumonia. A continuous glucose monitoring (CGM) based system with transmission of glucose data to a central system is used for remote monitoring of glucose levels and compared to standard finger-prick glucose. Blinded (to patients) CGM is mounted in the finger-prick group.
Epidemics and pandemics are a constant threat to health care systems globally. This stresses the importance of preparedness for a large amount of hospitalized quarantined patients in isolation, with the extra challenges it brings. The COVID-19 pandemic challenges the Danish health care system in many aspects: An increased number of citizens are expected to be admitted to hospital due to COVID-19 infected pneumonia and this will demand extra workforce resources, extra use of protective equipment (gowns, masks, gloves, etc) and extra time used for taking protective equipment on and off. In concert these extra demands will drain the health care system and any initiative to reduce these challenges is needed. In this randomized controlled trial, isolated patients with diabetes will be randomized to either standard care fingerprick glucose + blinded CGM or Dexcom G6 only.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
NONE
Enrollment
64
The investigational device is a CGM Dexcom G6. The Dexcom G6 System is intended to replace fingerstick blood glucose testing for diabetes treatment decisions. The device-system consists of a sensor, the Dexcom G6 device/sender, and connects to a smart device like a cellphone. The Dexcom G6 CGM system is probably the most precise system on the market and with no need for daily calibration with finger prick glucose. The Dexcom G6 sensor can last for 10 days without calibration and is approved for diabetes treatment decision making. Dexcom G6 has been extensively tested and is safe and approved even for pregnant women. The CE Marking confirms that the G6 system meets the Essential Requirements of the Medical Device Directive MDD 93/42/EEC as amended by 2007/47/EC.
Nordsjællands Hospital
Hillerød, Denmark
Time In Range (TIR) for blood glucose
TIR is presented in percent of time in which the participants' glucose values are in different glucose ranges.
Time frame: 1-2 weeks
Saved patient-personnel contacts related to blood glucose measurements.
Saved patient-personnel contacts related to blood glucose measurements, incl. time healthcare providers spent on diabetes related tasks and PPE related tasks, during the patients' hospitalization.
Time frame: 1-2 weeks
Glucose variations during hospitalization
Additional glucose outcomes based on data from Dexcom G6 are for example Time Above Range (TAR), Time Below Range (TBR), average glucose, variance in glucose (CV), etc.
Time frame: 1-2 weeks
Blood glucose lowering interventions
That is: Tablet-based and insulin-based regimens and number of times that sliding scale insulin (including dose of insulin) has been administered for each patient.
Time frame: 1-2 weeks
CGM sensor performance
Number of techincal errors during the sensors lifetime.
Time frame: 1-2 weeks
Course of hospital stay.
Hospital death (yes/no), length of stay at hospital, need for respiratory support (yes/no) and intensive care (yes/no), recovered vs. fatal (death within 60 days from admission).
Time frame: 1-2 weeks