Stillbirth (SB) is a devastating complication of pregnancy and contributes to over 2 million deaths globally every year. Over 20 million infants are born every year with low birth weight (LBW), which is associated with a twenty times increased risk of death in the first year of life and high rates of short- and long-term illnesses. Sleeping on one's back during pregnancy has recently emerged as a potential risk factor for LBW and SB in the medical literature. In high-income countries, SB rates have mostly remained the same in the past two decades and targeting modifiable risk factors could help reduce the number of SB and LBW in the population. When a pregnant woman sleeps on her back, her body position compresses underlying blood vessels and reduces blood flow to the developing baby. This body position could cause unpleasant symptoms for the mother and result in LBW or SB of her baby. Lying on her side or with a slight lateral tilt helps relieve this compression. One way to keep people off their back while sleeping is by using positional therapy (PT). It is a simple, safe, inexpensive and effective intervention for preventing people who snore or people who's breathing pauses during sleep from sleeping on their back. Reducing the amount of time pregnant women sleep on their back could help reduce SB and LBW rates. The investigators developed a PT device (PrenaBelt) and tested it in three clinical trials, which demonstrated that it significantly decreases the number of time women spend sleeping on their back. Using feedback from our previous research, the investigators developed five additional devices that will be tested in this study. The purpose of this study is to evaluate the new PrenaBelt (PB2) prototypes' ability to reduce the amount of time pregnant women sleep on their backs in the third trimester of pregnancy, validate the Ajuvia Sleep Monitor, and collect feedback on the devices. Demonstrating that the sleeping position of pregnant women can be modified through the use of a simple, inexpensive PT intervention may be one of the keys to achieving significant reductions in LBW and late SB rates in Australia and worldwide.
The ability of the PB2 prototypes to reduce the amount of time pregnant women spend sleeping on their backs at night in the home setting in the third trimester of pregnancy will be evaluated via a consecutive, six-night, in-home, controlled, cross-over sleep study in third trimester pregnant women where the Ajuvia Sleep Monitor is validated against infrared video on the first night. Six nights: the first night is a control night with infrared video recording where only the Ajuvia is worn in passive mode to collect data on the participant's body position and is followed by five nights with the five different prototypes. Randomization: The order in which the different devices will be worn on the second night through fourth night, inclusive, will be determined by simple randomization. This will minimize the potential impact of changes to sleep across the nights resulting from familiarization with the equipment as the sleep tests proceed through the five non-control nights, which could bias the results. For logistical reasons, the sixth night is non-randomized and will include the Ajuvia in 'active' mode Cross-over: After the first night, on each of the subsequent four nights, the participants will "cross over" to a different PB2 device (depending on their randomization order) and "cross over" to the Ajuvia in 'active' mode on the sixth night to allow each participant to act as her own control for comparison of treatment effect on outcomes. In home: conducting this study in the home setting will allow for a more accurate representation of sleep patterns as the participants will be in the comfort of their own bed. Sleep test: The maternal pelvis position will be recorded while the participants are sleeping using the Ajuvia device. Going to bed- and wake-times, as well as experience with each device will be recorded daily in a sleep diary.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Enrollment
6
PB2-1 prototype is a belt-like wearable device similar to the original PrenaBelt designed for pregnant women that permits supine positioning of the pelvis but, when in this position, provides subtle pressure points to the user's body and thereby activates the body's natural mechanism to reposition itself to relieve discomfort. It is expected to significantly decrease the amount of time a pregnant woman's pelvis is in the supine position overnight while promoting comfortable sleep.
PB2-2 prototype is a belt-like wearable device designed for pregnant women. When placed on the woman's back, this device prevents the pelvis from achieving a supine orientation by maintaining at least fifteen degrees of right or left lateral pelvic tilt. It is expected to significantly decrease the amount of time a pregnant woman's pelvis is in the supine position overnight while promoting comfortable sleep.
PB2-3 prototype is a belt-like wearable device designed for pregnant women. When placed on the woman's back, this device prevents the pelvis from achieving a supine orientation by maintaining at least fifteen degrees of right or left lateral pelvic tilt. It is expected to significantly decrease the amount of time a pregnant woman's pelvis is in the supine position overnight while promoting comfortable sleep.
PB2-4 prototype is a belt-like wearable device designed for pregnant women that prevents the user from achieving a supine position as the device allows right and left lateral pelvic tilt but prevents the user's pelvis from settling supine due to virtue of its design. It is expected to significantly decrease the amount of time a pregnant woman's pelvis is in the supine position overnight while promoting comfortable sleep.
PB2-5 prototype is a belt-like wearable device designed for pregnant women that does not provide positional therapy. It can be worn anytime as a maternity support belt.
Ajuvia Sleep Monitor senses the user's body position and can be used in passive or active mode with or without the PB2 prototypes. In the active mode, it alerts the woman when her pelvis is in the supine position through a gentle vibratory alarm.
Ajuvia Sleep Monitor senses the user's body position and can be used in passive or active mode with or without the PB2 prototypes. In the passive mode, it measures and records the position of the pelvis but does not alert the woman.
UniSA Clinical & Health Sciences
Adelaide, South Australia, Australia
Sensitivity of Ajuvia for supine position
The sensitivity(%) of the Ajuvia in determining the pelvic supine position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Specificity of Ajuvia for supine position
The specificity(%) of the Ajuvia in determining the pelvic supine position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Sensitivity of Ajuvia for prone position
The sensitivity(%) of the Ajuvia in determining the pelvic prone position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Specificity of Ajuvia for prone position
The specificity(%) of the Ajuvia in determining the pelvic prone position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Sensitivity of Ajuvia for left tilt position
The sensitivity(%) of the Ajuvia in determining the left pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Specificity of Ajuvia for left tilt position
The specificity(%) of the Ajuvia in determining the left pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Sensitivity of Ajuvia for left lateral position
The sensitivity(%) of the Ajuvia in determining the left lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Specificity of Ajuvia for left lateral position
The specificity(%) of the Ajuvia in determining the left lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Sensitivity of Ajuvia for right tilt position
The sensitivity(%) of the Ajuvia in determining the right pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Specificity of Ajuvia for right tilt position
The specificity(%) of the Ajuvia in determining the right pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Sensitivity of Ajuvia for right lateral position
The sensitivity(%) of the Ajuvia in determining the right lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Specificity of Ajuvia for right lateral position
The specificity(%) of the Ajuvia in determining the right lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.
Time frame: 1 night (approximately 8 hours)
Supine Sleep Time - Control
The time (in minutes) spent sleeping in the supine position with Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Supine Sleep Time - PB2-1
The time (in minutes) spent sleeping in the supine position with PB2-1 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Supine Sleep Time - PB2-2
The time (in minutes) spent sleeping in the supine position with PB2-2 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Supine Sleep Time - PB2-3
The time (in minutes) spent sleeping in the supine position with PB2-3 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Supine Sleep Time - PB2-4
The time (in minutes) spent sleeping in the supine position with PB2-4 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Supine Sleep Time - PB2-5
The time (in minutes) spent sleeping in the supine position with PB2-5 and Ajuvia in active mode
Time frame: 1 night (approximately 8 hours)
Prone Sleep Time - Control
The time (in minutes) spent sleeping in the prone position with Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Prone Sleep Time - PB2-1
The time (in minutes) spent sleeping in the prone position with PB2-1 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Prone Sleep Time - PB2-2
The time (in minutes) spent sleeping in the prone position with PB2-2 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Prone Sleep Time - PB2-3
The time (in minutes) spent sleeping in the prone position with PB2-3 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Prone Sleep Time - PB2-4
The time (in minutes) spent sleeping in the prone position with PB2-4 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Prone Sleep Time - PB2-5
The time (in minutes) spent sleeping in the prone position with PB2-5 and Ajuvia in active mode
Time frame: 1 night (approximately 8 hours)
Left-tilt Sleep Time - Control
The time (in minutes) spent sleeping in the left pelvic tilt position with Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-tilt Sleep Time - PB2-1
The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-1 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-tilt Sleep Time - PB2-2
The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-2 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-tilt Sleep Time - PB2-3
The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-3 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-tilt Sleep Time - PB2-4
The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-4 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-tilt Sleep Time - PB2-5
The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-5 and Ajuvia in active mode
Time frame: 1 night (approximately 8 hours)
Left-lateral Sleep Time - Control
The time (in minutes) spent sleeping in the left lateral position with Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-lateral Sleep Time - PB2-1
The time (in minutes) spent sleeping in the left lateral position with PB2-1 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-lateral Sleep Time - PB2-2
The time (in minutes) spent sleeping in the left lateral position with PB2-2 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-lateral Sleep Time - PB2-3
The time (in minutes) spent sleeping in the left lateral position with PB2-3 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-lateral Sleep Time - PB2-4
The time (in minutes) spent sleeping in the left lateral position with PB2-4 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Left-lateral Sleep Time - PB2-5
The time (in minutes) spent sleeping in the left-lateral position with PB2-5 and Ajuvia in active mode
Time frame: 1 night (approximately 8 hours)
Right-tilt Sleep Time - Control
The time (in minutes) spent sleeping in the right pelvic tilt position with Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-tilt Sleep Time - PB2-1
The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-1 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-tilt Sleep Time - PB2-2
The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-2 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-tilt Sleep Time - PB2-3
The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-3 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-tilt Sleep Time - PB2-4
The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-4 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-tilt Sleep Time - PB2-5
The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-5 and Ajuvia in active mode
Time frame: 1 night (approximately 8 hours)
Right-lateral Sleep Time - Control
The time (in minutes) spent sleeping in the right lateral position with Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-lateral Sleep Time - PB2-1
The time (in minutes) spent sleeping in the right lateral position with PB2-1 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-lateral Sleep Time - PB2-2
The time (in minutes) spent sleeping in the right lateral position with PB2-2 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-lateral Sleep Time - PB2-3
The time (in minutes) spent sleeping in the right lateral position with PB2-3 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-lateral Sleep Time - PB2-4
The time (in minutes) spent sleeping in the right lateral position with PB2-4 and Ajuvia in passive mode
Time frame: 1 night (approximately 8 hours)
Right-lateral Sleep Time - PB2-5
The time (in minutes) spent sleeping in the right lateral position with PB2-5 and Ajuvia in active mode
Time frame: 1 night (approximately 8 hours)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.