By comparing the preoperative data and postoperative data of 9 patients of microspherophakia, we concluded that the 6-point transscleral suture fixation of a 3-looped haptics posterior chamber intraocular lens (PC-IOL) through scleral pockets was a feasible method of PC-IOL implantation in the surgical treatment of microspherophakia.
Study Type
OBSERVATIONAL
Enrollment
9
Visual function
Best corrected visual acuity (BCVA) measured using a decimal chart
Time frame: 6 month postoperation
Visual function
uncorrected distance visual acuity (UDVA) measured using a decimal chart
Time frame: 6 month postoperation
Intraocular pressure
intraocular pressure measured using non-contact tonometer
Time frame: 6 month postoperation
PCIOL tilt degree
PCIOL tilt degree measured using Ultrasound biomicroscope
Time frame: 6 month postoperation
PCIOL decentration distance
PCIOL decentration distance measured using Ultrasound biomicroscope
Time frame: 6 month postoperation
Endothelial cell density
Endothelial cell density was measured by specular microscopy
Time frame: 6 month postoperation
Anterior chamber depth
Anterior chamber depth measured using Ultrasound biomicroscope
Time frame: 6 month postoperation