This study will evaluate the effect of posterior placement of orbital implants on their motility compared to intrascleral placement after evisceration .
Evisceration allows removal of the intraocular contents while preserving the sclera and normal extraocular muscle attachments. It is more advantageous than enucleation in patients in whom intraocular tumor is rules out. Maximizing orbital volume and restoration of movement are important aspects of a successful surgical outcome. Standard evisceration techniques do not allow placement of an implant larger than 13-16 mm which don't adequately replace the volume leading to postevisceration socket syndrome. Therefore, various techniques have been described to expand the scleral cavity and allow placement of a large implant including anterior sclerotomies, posterior sclerotomies, and disinsertion of optic nerve. Implant exposure is a terrible complication of evisceration with reported rates as high as 67%. Exposure of the implant can lead to infection, which usually mandates removal of the implant. Trying to minimize this risk, physicians intentionally place the implants posterior to the normal position of the globe. Some authors described placement of the implant posterior to posterior sclera which totally eliminated the risk of exposure. However, this deep seating of the implant may have deleterious effects on its motility. It can decrease implant-prosthesis interaction. In addition, retro-scleral placement of the implant moves it posterior to the pulleys that serve as the functional origins of rectus muscles. This relationship would be expected to alter the pulling directions of the rectus muscles after evisceration hindering effective implant motility. In this trial the investigators will try to study the effect of posterior placement of the implants on its motility after evisceration.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
30
Evisceration will be performed. Alloplastic orbital implant will be inserted either posterior to the sclera or partly within the scleral canal.
Mostafa Mohammed Mohammed Diab
Al Fayyum, Egypt
RECRUITINGImplant motility
The conjunctiva is marked at the center point of the implant while the patient looking in primary gaze. The excursion of the mark will be measured will a standard millimeter ruler in extreme gaze positions
Time frame: 6 months
Prosthesis motility
It will be measured with the kestenbaum's limbus test. Photographs will be taken while patients wearing Kestenbaum spectacles in vertical and horizontal directions of gaze.
Time frame: 6 months
Volume augmentation
Exophthalmometry will be performed for all patients after fitting a prosthesis. Enophthalmos is to be graded from 1 to 4 (grade 1 = no postoperative improvement; grade 2 = improvement \<2 mm but remained enophthalmos; grade 3 = improvement ≥2 mm but remained enophthalmos; and grade 4 = no enophthalmos) compared with unaffected side.
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.