Since the emergence of the new strain of betacoronavirus (SARS-CoV-2) and its important clinical repercussions, it has been described that patients with its associated pneumonia (COVID-19) have high rates of thrombotic events, including reduction in the dialyzers patency when undergoing renal replacement therapy. Several strategies for preventing the early loss of dialysers are described, and regional anticoagulation based on citrate is the preferred modality for preventing this complication. On the other hand, in patients with SARS-CoV-2 there are already descriptions of endothelial inflammation and activation of the coagulation cascade, including studies demonstrating the benefit of heparinization of these patients. Thus, this study aims to compare two different anticoagulation strategies in patients infected with COVID-19 with continued venovenous hemodialysis (CVVHD). From the indication of CVVHD, patients will be screened according to eligibility criteria and, if they fit these parameters, they will be randomized into two groups: Group A - Standard regional anticoagulation based on Citrate associated with infusion of low doses of unfractionated heparin 10ui/kg/hour and Group B - Standard regional anticoagulation based on Citrate only. Patients will be randomized in blocks and followed for 72 hours. The primary endpoint is dialyzer patency at the end of 72 hours of clinical follow-up. Secondary objectives will be mortality, bleeding rate, drop in hematimetric indices, urea sieving, filter time in hours, down time of therapy, system and dialyser pressures (PBE and PTM). All patients will undergo a standard procedure with a prescribed dose of 30mL/Kg/H, blood flow of 150mL/minute and polysulfone dialyzer.
After randomization, patients will be allocated to one of two groups: Control group (n = 45): patients on continuous hemodialysis (blood flow 150 ml / min, dose of 30 ml / kg / h) receiving anticoagulation with sodium citrate at 4 mmol / l. The dialysis system pressures, dialyzer patency and duration and bleeding rate will be assessed for 72 hours; Intervention group (n = 45): patients on continuous hemodialysis (blood flow 150 ml / min, dose of 30 ml / kg / h) receiving anticoagulation with sodium citrate at 4 mmol / l associated with unfractionated heparin at 10U / Kg / h. The dialysis system pressures, dialyzer patency and duration and bleeding rate will be assessed for 72 hours.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
118
Addition of unfractioned heparin to CVVHD system already running under citrate regional anticoagulation.
University of São Paulo General Hospital
São Paulo, São Paulo, Brazil
Clotted dialyzers
The percentage of clotted dialyzers within 72 hours in each of the studied groups.
Time frame: Day 3 of dialysis
Time-free of clotting
Number of hours until a dialyzer clots in the first 72 hours of dialysis
Time frame: Day 3 of dialysis
Number of dialyzers used
The amount of dialyzers used in the first 72 hours of hemodialysis
Time frame: Day 3 of dialysis
Pressure variation
Variation in dialysis system and vascular access pressures in the first 72 h of dialysis
Time frame: Day 3 of dialysis
Urea sieving
Variation in urea sieving between the first, second and third days of dialysis
Time frame: Day 3 of dialysis
Downtime of dialysis
Time of dialysis stop due to clotting in the first 72 hours
Time frame: Day 3 of dialysis